O.  Optional Remote Display HBR-3100 

 

Warning: 

AC mains supply must be disconnected completely from the battery charger before plugging 

in of the Remote Display HBR-3100. Otherwise the charger will be damaged. 

 

I.  Introduction 
 

The Remote Display comes with 10m extension cable with interconnector. 
When the optional remote HBR-3100 is installed, it will display the real time charging stage, voltage & amperage, battery type set, 
max.  power  level  set,  type  of  fault  with  alarm,  etc  and  can  remote  control  the  output  terminal  On/OFF,  trigger  the  Equalization 
charging for wet battery and force charger to float mode.   
It can be mounted on BC charger by replacing the dummy cover on the front panel or  remotely mounted with 10m extension cable 
going through the unplugged hole at the front of the dummy panel. 
 

II.  Connection 
 

 

1. 

10 Meters Phone Cable 

2. 

In Line Coupler 6P6C 

3. 

HBR-3100 Remote Display Module 

 

a. 

Take out the dummy remote panel from charger and remove the black hole plug from the dummy remote panel

 

 

b. 

Remote cable through the dummy remote panel’s hole.

 

 

Hole plug 

Содержание BC-1240P-1AP

Страница 1: ...f a battery Never smoke use an open flame or create sparks near battery or charger during normal charging operation as Batteries may give out explosive gas Do not charge batteries in a sealed enclosur...

Страница 2: ...and Calcium Calcium lead acid batteries There are two user programmable charging profiles for the professional users through USB port by personal computer In addition the programmed maintenance charge...

Страница 3: ...Sensor Socket Connection to Battery Temperature sensor accessory Sensor to increase decrease charging voltage at low high battery temperature B Using the charger 1 Check the supplied accessories AC c...

Страница 4: ...ry charger in a well ventilated place make sure the mounting surface is flat and without soft covering material or loose paper sheet The air intake is at the bottom and air outlet at the back Make sur...

Страница 5: ...s to Float Stage The max Absorption time is also controlled by the time in Bulk charge and battery type selected Stage 3 THE UO PHASE The constant voltage charging Float LED is ON In Float stage the b...

Страница 6: ...ce the Voltage of each cell reverse the high concentration of electrolyte at the bottom and clear up large sulfate crystals on the plates You can use the Equalization Selection Switch 8 to perform the...

Страница 7: ...duced output power OFF OFF ON At reduced output power as selected Indicates xx Power Set This is not a fault So no specific indication Battery over heat detected by remote temp sensor at 60 C Flashing...

Страница 8: ...elect switch in wrong setting Battery capacity too large Ambient temperature too low Battery has damaged cell or battery is too old Wrong set the lower power level Check for loose contact right cable...

Страница 9: ...recovers Automatically after Fault Condition is Removed Short Circuit Recovers Automatically if Fault Condition is Removed within 20 seconds Otherwise the charger will shutdown until re start the cha...

Страница 10: ...level set type of fault with alarm etc and can remote control the output terminal On OFF trigger the Equalization charging for wet battery and force charger to float mode It can be mounted on BC char...

Страница 11: ...output ON and OFF Green LED is illuminated when output is ON 2 Alarm Can be silenced or audible by toggling this button default is audible Red LED will illuminate when fault occurred 3 Func To toggle...

Страница 12: ...r Level Display current output level 10 Software Version Displays the current control software version Remote Short cut 1 Press and hold the SET button for 5 seconds and release the button to enter Eq...

Отзывы: