VOLTCRAFT WB-200 Скачать руководство пользователя страница 5

5

5. Safety instructions

These instructions contain important information on how to use the thermal imaging camera cor-

rectly. Please read them carefully before using the thermal imaging camera for the first time. 
Damage caused due to failure to observe these instructions will void the warranty. We shall not 

be liable for any consequential damage. We shall not be liable for damage to property or personal 

injury caused by incorrect handling or failure to observe the safety information! Such cases will 

void the warranty/guarantee. 
•  This device was shipped in a safe condition. 
•  To ensure safe operation and to avoid damaging the device, always observe the safety information and 

warnings in these instructions. 

•  The unauthorized conversion and/or modification of the device is not permitted for safety and certification 

reasons.

•  Consult an expert when in doubt about the operation, safety or connection of the device
•  Measuring instruments and their accessories are not toys and must be kept out of the reach of children.
•  Always comply with the accident prevention regulations for electrical equipment when using the product 

in commercial facilities. 

•  In schools, educational facilities, hobby and DIY workshops, measuring instruments must be used under 

the responsible supervision of qualified personnel. The same applies when the measuring instrument is 

used by people with reduced physical and mental capabilities. 

•  Do not use in the immediate vicinity of strong magnetic or electromagnetic fields, transmitter aerials or 

RF generators. These may distort the measurements. 

•  If you suspect that safe operation is no longer possible, stop using the device immediately and prevent 

unauthorized use. Safe operation can no longer be assumed if: 

 - There are signs of damage 
 - The device does not function properly 
 - The device was stored under unfavourable conditions for a long period of time 
 - The device was subjected to rough handling during transport. 

•  Do not switch the device on immediately after it has been brought from a cold room into a warm one. The 

condensation generated may destroy the product. Leave the device switched off and allow it to reach 

room temperature. 

•  Do not leave packaging material lying around carelessly, as it may become a dangerous toy for children. 
•  Store the device in a safe place where it cannot fall down! Otherwise, this could cause injuries. 
•  Never place the measuring instrument on a flammable surface (e.g. carpet) during charging. Always use 

a suitable, non-flammable, heatproof surface.

•  Ensure adequate ventilation during charging. Never cover the measuring instrument during charging. 
•  Never charge defective or damaged rechargeable batteries.

Содержание WB-200

Страница 1: ...Operating instructions WB 200 thermal imaging camera Item No 1897504...

Страница 2: ...ng the memory card 9 11 Setup 9 a Turning the camera on and off 9 b Control keypad 10 c Display elements and symbols 11 d System settings 12 e Setting the measurement range 15 f Setting the temperatur...

Страница 3: ...ident that starting with Voltcraft will be the beginning of a long successful relationship We hope you enjoy your new Voltcraft product If there are any technical questions please contact Internationa...

Страница 4: ...ion class IP54 It is dustproof and splashproof The camera has no ATEX protection Do not operate the camera in potentially explosive atmospheres Ex Do not operate the camera under adverse environmental...

Страница 5: ...ts must be used under the responsible supervision of qualified personnel The same applies when the measuring instrument is used by people with reduced physical and mental capabilities Do not use in th...

Страница 6: ...on battery from the device Do not charge discharge damaged leaking or deformed rechargeable batteries This may cause a fire or explosion Dispose of unusable rechargeable batteries in an environmentall...

Страница 7: ...of the reach of children Do not leave batteries lying around as there is a risk that children or pets may swallow them Observe the safety information in each section 7 Operating elements 1 Back button...

Страница 8: ...d This creates a fire hazard The camera becomes hot during charging Place the camera on a flat robust and heat resistant surface Inserting the rechargeable battery into the camera and removing the rec...

Страница 9: ...can then easily remove the card Carefully close the rubber cover to ensure protection against moisture and dust If the memory card is not recognised when triggering memory with the red trigger button...

Страница 10: ...then automatically power off after a preset time SET button 2 The SET button opens the settings menu In the settings menu this button is used as a selection button Enter when pressed briefly Use the...

Страница 11: ...Symbol for setting the colour palettes 4 Image gallery symbol for displaying the stored thermal images 5 Symbol for system settings 6 Emission level display 7 Date display 8 Time display 9 Temperatur...

Страница 12: ...ttons to select the respective parameters and press the SET button to confirm the selection Use the Back button 1 to exit the menu item The system menu has the following setting functions Original Nat...

Страница 13: ...cture The following table provides an overview of the menu structure and the setting options after switching the menu language to your national language Language German English Date Time DD MM YYYY MM...

Страница 14: ...odel WB 200 Capacity xxxx Available xxxx Version xxx Product ID XXXXXXXXX Recovery No Yes Format SD No Yes The duration of the formatting process depends on the memory card size Formatting will be dis...

Страница 15: ...ge In this case however the detail display is reduced This range can be used for rough overview measurements Auto The camera automatically sets the respective mode to be displayed To set the measureme...

Страница 16: ...centre and cannot be changed High Low The lowest measuring point is marked with a blue frame and the letter L in the image The highest measuring point is marked with a red frame and the letter H in t...

Страница 17: ...in rainbow mode Grey palette The cool spots are displayed in black and become brighter in the grey range for the hot spots Here the cold to hot contrast ratio is the greatest To set the colour palett...

Страница 18: ...ns to select the image gallery symbol and press the SET button to confirm the selection Use the cursor buttons to select the corresponding image and press the SET button to confirm the selection Use t...

Страница 19: ...haracteristics of a material The higher this value the more radiation a material can emit Many organic materials and surfaces have an emission level of approx 0 95 Metallic surfaces or shiny materials...

Страница 20: ...e saving and tick to save the image The measuring instrument will create a separate folder named Images in the memory card The images can be stored with a time stamp in the file name as follows img Da...

Страница 21: ...ce of the measuring instrument In addition the vapours emitted by these substances are explosive and harmful to your health Do not use sharp edged tools screwdrivers or metal brushes to clean the devi...

Страница 22: ...the left Used batteries can be returned to local collection points our stores or battery retailers That way you fulfil your statutory obligations and contribute to the protection of the environment 1...

Страница 23: ...al sensitivity NETD 150 mK Field of view FOV 50 x 38 Geometric resolution IFOV 11 mrad Refreshing rate 9 Hz Focus focus free fix focus Minimum focus area 25 cm Spectral range 8 14 m Colour LC display...

Страница 24: ...ed Reproduction by any method e g photocopy microfilming or the capture in electronic data processing systems require the prior written approval by the editor Reprinting also in part is prohibited Thi...