d) System settings 

The measuring instrument allows the system data relevant to the user to be set via a menu. Such data includes the 

menu language, units of measurement, time and date, etc. 
These system settings must be made in advance so measurements can be stored with a time stamp, etc. 
•  When the measuring instrument is on, press the SET button to return to the main menu. 
•  Press the “left arrow” (4) or “right arrow” (8) cursor buttons until the gear symbol   is marked. 
•  Press the “SET” button to confirm the selection. The system settings menu will now open.

Due to the size of the display, only seven menu areas can be displayed. Use the cursor buttons (4/8) to move the 

menu. The selected menu item will be highlighted in colour.

•  To activate the menu item, press the “SET” button.
•  Use the cursor buttons to select the respective parameters and press the “SET” button to confirm the selection.
•  Use the “Back” button (1) to exit the menu item.
The system menu has the following setting functions:

Original 

National 

language 

Meaning 

Language 

Sprache 

Menu language selection 

Date/Time 

Datum/Zeit 

Date and time setting 

Emissivity

Emissivität

Emission level setting

Auto OFF

Auto Aus

Automatic power-off setting

Brightness

Helligkeit

Setting the display brightness

Temp Unit 

Temp Einheit 

Temperature unit setting 

Temperature Alarm Temperatur Alarm Setting for temperature alarms when exceeding or falling below 

certain levels

About

Systeminfo

System data display (model, memory card size, software version, etc.)

Format SD

Format SD

Formatting the memory card

Recovery

Wiederherstellen

Restore to factory settings

Auto Save

Auto Speichern

Setting whether images should be saved without a new query after 

pressing the memory button. 

Temp Bar

Farbbalken

Display of colour distribution as a bar

Содержание WB-200

Страница 1: ...Operating instructions WB 200 thermal imaging camera Item No 1897504...

Страница 2: ...ng the memory card 9 11 Setup 9 a Turning the camera on and off 9 b Control keypad 10 c Display elements and symbols 11 d System settings 12 e Setting the measurement range 15 f Setting the temperatur...

Страница 3: ...ident that starting with Voltcraft will be the beginning of a long successful relationship We hope you enjoy your new Voltcraft product If there are any technical questions please contact Internationa...

Страница 4: ...ion class IP54 It is dustproof and splashproof The camera has no ATEX protection Do not operate the camera in potentially explosive atmospheres Ex Do not operate the camera under adverse environmental...

Страница 5: ...ts must be used under the responsible supervision of qualified personnel The same applies when the measuring instrument is used by people with reduced physical and mental capabilities Do not use in th...

Страница 6: ...on battery from the device Do not charge discharge damaged leaking or deformed rechargeable batteries This may cause a fire or explosion Dispose of unusable rechargeable batteries in an environmentall...

Страница 7: ...of the reach of children Do not leave batteries lying around as there is a risk that children or pets may swallow them Observe the safety information in each section 7 Operating elements 1 Back button...

Страница 8: ...d This creates a fire hazard The camera becomes hot during charging Place the camera on a flat robust and heat resistant surface Inserting the rechargeable battery into the camera and removing the rec...

Страница 9: ...can then easily remove the card Carefully close the rubber cover to ensure protection against moisture and dust If the memory card is not recognised when triggering memory with the red trigger button...

Страница 10: ...then automatically power off after a preset time SET button 2 The SET button opens the settings menu In the settings menu this button is used as a selection button Enter when pressed briefly Use the...

Страница 11: ...Symbol for setting the colour palettes 4 Image gallery symbol for displaying the stored thermal images 5 Symbol for system settings 6 Emission level display 7 Date display 8 Time display 9 Temperatur...

Страница 12: ...ttons to select the respective parameters and press the SET button to confirm the selection Use the Back button 1 to exit the menu item The system menu has the following setting functions Original Nat...

Страница 13: ...cture The following table provides an overview of the menu structure and the setting options after switching the menu language to your national language Language German English Date Time DD MM YYYY MM...

Страница 14: ...odel WB 200 Capacity xxxx Available xxxx Version xxx Product ID XXXXXXXXX Recovery No Yes Format SD No Yes The duration of the formatting process depends on the memory card size Formatting will be dis...

Страница 15: ...ge In this case however the detail display is reduced This range can be used for rough overview measurements Auto The camera automatically sets the respective mode to be displayed To set the measureme...

Страница 16: ...centre and cannot be changed High Low The lowest measuring point is marked with a blue frame and the letter L in the image The highest measuring point is marked with a red frame and the letter H in t...

Страница 17: ...in rainbow mode Grey palette The cool spots are displayed in black and become brighter in the grey range for the hot spots Here the cold to hot contrast ratio is the greatest To set the colour palett...

Страница 18: ...ns to select the image gallery symbol and press the SET button to confirm the selection Use the cursor buttons to select the corresponding image and press the SET button to confirm the selection Use t...

Страница 19: ...haracteristics of a material The higher this value the more radiation a material can emit Many organic materials and surfaces have an emission level of approx 0 95 Metallic surfaces or shiny materials...

Страница 20: ...e saving and tick to save the image The measuring instrument will create a separate folder named Images in the memory card The images can be stored with a time stamp in the file name as follows img Da...

Страница 21: ...ce of the measuring instrument In addition the vapours emitted by these substances are explosive and harmful to your health Do not use sharp edged tools screwdrivers or metal brushes to clean the devi...

Страница 22: ...the left Used batteries can be returned to local collection points our stores or battery retailers That way you fulfil your statutory obligations and contribute to the protection of the environment 1...

Страница 23: ...al sensitivity NETD 150 mK Field of view FOV 50 x 38 Geometric resolution IFOV 11 mrad Refreshing rate 9 Hz Focus focus free fix focus Minimum focus area 25 cm Spectral range 8 14 m Colour LC display...

Страница 24: ...ed Reproduction by any method e g photocopy microfilming or the capture in electronic data processing systems require the prior written approval by the editor Reprinting also in part is prohibited Thi...

Отзывы: