Technical data
a) Device data
Power supply ................................ 1x 9 V battery
Battery life ..................................... 50 hours
Power consumption ...................... 4.9 µA
Resolution ..................................... 1 unit
Precision ....................................... ±1 unit
Measurement range ..................... 0 - 100 units
Measuring depth ........................... 20 - 40 mm
Screw connection (stand) ............. 6.3 mm (1/4")
Operating conditions ..................... 0 to +50 ºC, <70 %
Storage conditions ........................ -10 to +60 ºC, <80 %
relative humidity (non-condensing)
Dimensions (H x W x D) ............... 194 x 54 x 34 mm
Weight .......................................... 143 g (without battery)
b) Moisture level limits
The following limits can be used as a reference.
Construction
material
Moisture range (unit)
Moisture status
Hard plaster
<30
DRY
30 - 60
RISK
>60
WET
Cement
<25
DRY
25 - 50
RISK
>50
WET
Wood
<50
DRY
50 - 80
RISK
>80
WET
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or the capture in
electronic data processing systems) requires prior written approval from the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
Copyright 2018 by Conrad Electronic SE.