b) Persons and product

•  If the device is moved from a cold into a warm environment, condensation can 

form inside the device. This can result in incorrect measurements. Leave the 

device for a while to adjust to the new ambient conditions before commencing 

operation.

•  The user is responsible for the measured results from this device. We neither 

guarantee nor assume responsibility for the correctness of the measured results. 

Under no circumstances shall we assume responsibility for any damage caused 

by application of the measured results.

c) (Rechargeable) battery

•  Always check that the battery is inserted with the correct polarity.
•  To prevent battery leakage, the battery should be removed from the device if it 

is not used for a long period of time. Leaking or damaged batteries may cause 

acid burns if they come into contact with your skin. Always use suitable protective 

gloves when handling damaged batteries.

•  Batteries must be kept out of the reach of children. Do not leave batteries lying 

around, as there is a risk that children or pets may swallow them.

•  Batteries  must  not  be  dismantled,  short-circuited  or  thrown  into  flames.  Never 

recharge non-rechargeable batteries. Danger of explosion!

Product overview

Moisture measuring device

1

2

3
4
5

7

8

6

1  Moisture sensor
2  LC display

DOWN

 button

SET

 button

MEAS

 button

6  On/off button 

UP

 button

8  Battery compartment (on rear)

LC display

11

12
13
14

15

17

16

9

10

18

9  Low battery indicator
10  “HOLD” data storage symbol
11  “DRY” status symbol
12  “RISK” status symbol
13  “WET” status symbol (moist status)
14  “MIN” symbol
15  Min. moisture level
16  Max. moisture level
17  “MAX” symbol
18  Current moisture level

Setup

a) Inserting and replacing the batteries

The moisture measuring device is operated via a 9 V block battery. The battery is included 

separately. The battery must be inserted into the moisture measuring device. 
To insert the battery, proceed as follows:
•  With the aid of a screwdriver, remove the battery compartment cover from the rear of the 

measuring device.

•  Insert a new 9 V block battery into the battery compartment, paying attention to the correct 

polarity (8). Ensure that the device's contacts are seated correctly.

•  Replace the battery compartment cover and screw down tightly.
•  Replace the battery if the low battery indicator (9) lights up on the LC display.

  Ensure that the moisture measuring device is switched off before you replace the 

battery.

•  To replace the battery, proceed as described above. Remove the empty battery from the 

battery compartment before inserting a new battery.

 Operating instructions

MF-90 material moisture measuring device

Item no. 1611424

Intended use

The product is intended to be used for non-invasive, digital moisture measurement. It is ideal 

for measuring the moisture level in concrete, wood and other construction materials. The 

device can help in checking whether or not the surface is suitable for painting or coating. Large 

surfaces can also be measured quickly and effectively with the signal function. The user can 

concentrate on the object that is being measured without having to constantly read off the 

measured values on the display. The device emits a signal when the moisture level exceeds 

the limit value. The limit value can be adjusted. The device offers a measuring depth of around 

20 - 40 mm and a wide measurement range and is equipped with a display of min./max. values 

and a low battery indicator. The device is operated via a 9 V block battery. It also has an 

automatic shut-off function.
For safety and approval purposes, you must not rebuild and/or modify this product. Using the 

product for purposes other than those described above may damage the product. In addition, 

improper use can cause hazards such as a short circuit or fire. Read the operating instructions 

carefully and store them in a safe place. Only make this product available to third parties 

together with its operating instructions.
This product complies with statutory, national and European regulations. All company and 

product names are trademarks of their respective owners. All rights reserved.

Delivery content

•  Moisture measuring device
•  1x 9 V block battery
•  Operating instructions

Up-to-date operating instructions  

Download the latest operating instructions at www.conrad.com/downloads or scan the QR code 

shown. Follow the instructions on the website.

Explanation of symbols

  The symbol with an exclamation mark in a triangle is used to highlight important 

information in these operating instructions. Always read this information carefully.

  The arrow symbol indicates special information and advice on how to use the 

product.

Safety information

Read the operating instructions and safety information carefully. If you do 

not follow the safety information and information on proper handling in these 

operating instructions, we will assume no liability for any resulting personal 

injury or damage to property. Such cases will invalidate the warranty/

guarantee.

a) General information

•  The device is not a toy. Keep it out of the reach of children and pets.
•  Do not leave packaging material lying around carelessly. It may become a 

dangerous toy for children.

•  Protect the product from extreme temperatures, direct sunlight, strong jolts, high 

humidity, moisture, flammable gases, vapours and solvents.

•  Do not place the product under any mechanical stress.
•  If it is no longer possible to operate the product safely, take it out of operation and 

protect it from any accidental use. Safe operation can no longer be guaranteed 

if the product:

 - is visibly damaged, 
 - is no longer working properly, 
 - has been stored for extended periods in poor ambient conditions or 
 - has been subjected to any serious transport-related stresses.

•  Please handle the product carefully. Jolts, impacts or a fall even from a low height 

may damage the product.

•  Consult a technician if you are not sure how to use or connect the product, or if 

you have concerns about safety.

•  Maintenance, modifications and repairs must be carried out by a technician or a 

specialist repair centre.

•  If you have questions which remain unanswered by these operating instructions, 

contact our technical support service or other technical personnel.

Содержание 1611424

Страница 1: ...erden Der Benutzer kann sich auf das Objekt konzentrieren das gemessen wird ohne st ndig die Messwerte auf der Anzeige ablesen zu m ssen Das Ger t erzeugt einen Signalton wenn der Feuchtegrad den Gren...

Страница 2: ...ert haben ver ndern Sie nicht die Position der Hand in der anschlie end darauf folgenden Messung Messkalibrierung und Messung m ssen mit der gleichen Handposition durchgef hrt werden denn eine Ver nde...

Страница 3: ...n Verpflichtungen und leisten Ihren Beitrag zum Umweltschutz Technische Daten a Ger tedaten Stromversorgung 1 x 9 V Batterie Batterielebensdauer 50 Stunden Stromverbrauch 4 9 A Aufl sung 1 Einheit Pr...

Страница 4: ...the signal function The user can concentrate on the object that is being measured without having to constantly read off the measured values on the display The device emits a signal when the moisture...

Страница 5: ...5 to freeze a value on the display HOLD appears on the display 10 in addition to the last measured value If HOLD mode is not terminated by pressing the MEAS button 5 the measured values are displayed...

Страница 6: ...as a reference Construction material Moisture range unit Moisture status Hard plaster 30 DRY 30 60 RISK 60 WET Cement 25 DRY 25 50 RISK 50 WET Wood 50 DRY 50 80 RISK 80 WET This is a publication by C...

Страница 7: ...nt galement tre mesur es rapidement et efficacement l aide de la fonction signal L utilisateur peut se concentrer sur l objet mesurer sans devoir constamment lire les valeurs de mesure sur l affichage...

Страница 8: ...Lorsque vous avez calibr l appareil pour effectuer une mesure ne changez pas la position de votre main pour r aliser ensuite la mesure Le calibrage et la mesure doivent tre effectu s avec une positio...

Страница 9: ...ez ainsi les ordonnances l gales et contribuerez la protection de l environnement Donn es techniques a Donn es de l appareil Alimentation en nergie 1x pile de 9 V Dur e de vie des piles 50 heures Cons...

Страница 10: ...an zich op het object concentreren zonder voortdurend de meetwaarden op het display te moeten aflezen Het apparaat produceert een geluidssignaal wanneer de vochtigheidsgraad boven de grenswaarde komt...

Страница 11: ...tgevoerd Een verandering van de positie van de hand ten opzichte van de kogelkop van de vochtsensor 1 leidt tot meetfouten Houd de kogelkop van de vochtigheidssensor 1 in een rechte hoek op het opperv...

Страница 12: ...an het milieu Technische gegevens a Toestelgegevens Stroomvoorziening 1x 9 V batterij Gebruiksduur batterij 50 uur Stroomverbruik 4 9 A Resolutie 1 eenheid Precisie 1 eenheid Meetbereik 0 100 eenheden...

Отзывы: