OWNERS MANUAL
PAGURO 2000
23
3. STARTING/STOPPING PROCEDURE
CAUTION:
All AC loads must be switched off
before starting. This precaution will prevent damage
caused by unanticipated operation of AC machinery
and will prevent a cold engine from stalling.
PREHEATING
This generator has a 12VDC electric starter.
To preheat push contemporaneously the START and STOP and keep pushed for 10 seconds. The green led on the remote
control panel will be lighted.
STARTING OPERATION
Release the STOP button and keep the START button pushed, the yellow start indicator light will come on and start to blink.
Once the engine fires and runs, the yellow start indicator light will go out and the green run indicator light will come on.
NOTE: If a start attempt is aborted, the yellow indicator light will continue to blink. To reset the circuit, press the
STOP button.
Apply a light load to the generator and allow the engine to warm up to operating temperature before applying heavy
loads.
NOTE: Some unstable running may occur in a cold engine. This condition should smooth out as the engine warms up and
when the generators loads are applied.
OPERATING THE GENERATOR
After the generator has started, run it with a medium load for warm up. If possible, apply the load in stages.
CAUTION:
Never operate the engine for long periods of time
without an amperage load being applied, otherwise
carbon build-up may occur which can cause severe
damage to the engine.
INITIAL START-UP CHECK LIST
Check for possible leaks from all the connections inside the sound-shield.
Make sure the cooling water is discharging properly, outboard from the exhaust outlet.
Make certain that the generator is mounted securely.
Listen for unusual sounds and vibrations.
STOPPING THE GENERATOR
Remove the AC loads from the generator one at a time and allow the generator to run for an additional 3 to 5 minutes (this
stabilizes its operating temperature).
To stop the generator, press the STOP button on the control panel; shutdown is automatic.
Check the lube oil level a few minutes after stopping the engine, because lube oil from the bearings etc. continues to drain
down into the oil sump. Disregarding this fact and not maintaining the proper oil level may lead to overfilling, causing
overheating and the possibility of engine runway.
After shutdown, carefully inspect the generator. Check for possible leaks from all the connections inside the sound-shield.