42.VW.2210.2554_BA_V02_EN
VAS 6923A
18
EN | Operation
Flashing code
Meaning
Corrective action
Charging cable is
overheating
Leave the AC charging cable to cool down for
at least 15 minutes.
Reposition the AC charging cable if necessary.
Observe the permitted ambient conditions
(see the “Technical data” section) and the
safety instructions (see the “Important safety
instructions” section).
Restart the charging process.
Direct current
fault
Restart the charging process.
If the fault persists, the vehicle isolation must be checked by a person
qualified to do so in accordance with DGUV 200-005 (level 2 at
minimum).
Alternating
current fault
Switch off the circuit breaker for the power
supply connected to the AC charging cable!
This automatically ends the charging process.
Check the supply cable on the power supply
side, starting from the power outlet to the AC
charging cable.
a.
Replace the product if damaged. Contact the manufacturer.
b.
Contact an electrician to ensure that the AC supply is correct.
Restart the charging process.
If the fault persists, the vehicle isolation must be checked by a person
qualified to do so in accordance with DGUV 200-005 (level 2 at
minimum).
Communication
error
Restart the charging process.
Device error
Contact the manufacturer.