background image

Alveo Programming 
Cable User Guide 

UG1377 (v2019.

1

) September 17, 2019 

Summary of Contents for Alveo U50

Page 1: ...Alveo Programming Cable User Guide UG1377 v2019 1 September 17 2019...

Page 2: ...rovided names of the supported cards and links to each Chapter 2 Preventing ESD Damage Updated Figure 1 Updated Tables 1 4 Chapter 3 Setting Up the System Updated Figures 2 7 Revised steps to set up r...

Page 3: ...Component Descriptions 6 Chapter 3 Setting Up the System with the Programming Cable 8 Connecting the Ribbon Cable 8 Disconnecting the Ribbon Cable 10 Connecting Alveo Programming Module to Card 10 Cha...

Page 4: ...Alveo programming cable consists of a programming module ribbon cable and USB cable Debug port enabled Alveo cards have a 2x15 pin connector which connects to the programming module via the ribbon cab...

Page 5: ...nd Alveo card Used for programming the FPGA 2 Micro USB Connector Port 1 Provides connection between host system with Vivado installed and the programming module Used for programming the Alveo card 3...

Page 6: ...ions Debug Header for Main Board Interconnection The programming module is populated with a 2x15 pin debug connector Callout 1 in Figure 1 which connects to the Alveo card via a ribbon cable 2x15 Conn...

Page 7: ...Description MANF MANF_P N Remarks 1 1 Ribbon Cables IDC Cables 050 Tiger Eye IDC Ribbon Cable Assembly 1 27 mm 30 Position 6 length Female to Female Samtec FFSD 15 D 06 00 01 N Connection between pro...

Page 8: ...ey IMPORTANT The ribbon length you use can vary depending on your system setup For ribbon cable length greater than 5 it is necessary to reduce the JTAG transfer frequency used by Vivado hardware mana...

Page 9: ...apply gentle pressure and ensure the cable has a tight connection IMPORTANT Do not apply excessive force when connecting the ribbon cable as the connector pins can be damaged or bent CAUTION When inst...

Page 10: ...er for ribbon cable access 1 Before installing the Alveo card connect one end of the ribbon cable to the 2x15 pin maintenance port on the Alveo card following the instructions outlined in Connecting t...

Page 11: ...Alveo Programming Module An image of both the ribbon on the left side and USB connected on the right side is shown below Figure 7 Alveo Programming Module with Ribbon and USB Cables Connected 7 Guide...

Page 12: ...on your host machine or laptop Alveo card must be installed see Connecting Alveo Programming Module to Card and the server powered on DMC connected as described in Connecting Alveo Programming Module...

Page 13: ...e manager command line as shown in the below image set_property PARAM FREQUENCY 1000000 current_hw_target Figure 9 Changing JTAG Transfer Frequency via TCL Command 5 Choose the memory configuration pa...

Page 14: ...7 In the Address Range drop down list select Entire Configuration Memory Device 8 Click OK Figure 11 Program Configuration Memory 9 Disconnect the card in the Vivado hardware manager 10 Disconnect the...

Page 15: ...endix A Board Specifications Dimensions Square Form Factor Height 2 5 inch 6 35 cm Length 2 5 inch 6 35 cm Thickness 5 0 062 inch 0 1574 cm Environmental Temperature for U200 and U280 Operating 0 C to...

Page 16: ...rior written consent Certain products are subject to the terms and conditions of Xilinx s limited warranty please refer to Xilinx s Terms of Sale which can be viewed at https www xilinx com legal htm...

Reviews: