41.VW.2210.3102_BA_V00_EN
VAS 681 003A
37
EN | Operation
Parameter
Values
Meaning
Unit
(Control
Pilot)
“A” = No communication with the vehicle.
“B” = Communication established, charging not
active.
“C” = Communication established, charging
active.
Charge phase
Status of the charging process.
Voltage
Max
Charging end voltage
V
Act
Current voltage at the output of the high-
voltage DC charger
Current
Set
Maximum possible charging current of the
high-voltage DC charger
A
Act
Current charging current of the high-voltage DC
charger
Temp. AC
Input
Temperature at the AC input of the high-
voltage DC charger
°C
Output
Temperature just before the input of the AC/DC
converter
Temp. DC
Input
Temperature just after the output of the AC/DC
converter
°C
Output
Temperature at the DC output of the high-
voltage DC charger
Temp. CCS
DC+
Temperature at the positive pin of the CCS plug °C
DC-
Temperature at the negative pin of the CCS plug
Temp. AC/DC
Temperature of AC/DC converters 1 and 2
°C
Temp.
Derating
Indicates the power reduction due to
temperature limits.
%
Insulation 1
Z+/Z-
Resistance values between DC+, PE and DC-
kΩ/MΩ
Insulation 2
Z+/Z-
Resistance values as a function of the actual
voltage
kΩ/V
INS OK
Insulation monitoring status