41.VW.2210.3102_BA_V00_EN
VAS 681 003A
10
EN | Safety
Pressing the emergency stop button
Push in the emergency stop button until it clicks into place.
The message “
Emergency stop pressed
” appears on the LC display.
Resetting the emergency stop button
Turn the emergency stop button clockwise and pull out until it clicks into place.
Press the “On” button.
The message “
Emergency stop pressed
” disappears from the LC display.
You cannot resume a previous charging process by resetting the emergency stop button.
You have to restart the product.
Intended use
The high-voltage DC charger is a mobile charger for rapidly charging traction batteries in
electric vehicles. The high-voltage DC charger is used to charge traction batteries with direct
current in charging mode 4.
The high-voltage DC charger has a type 1 CCS charging plug, dynamic power adjustment and
control and protection functions that make it suitable for all the conventional electric
vehicles available on the market.
Use the high-voltage DC charger only on the DC charging socket of your electric vehicle!
Connect the high-voltage DC charger only to fused power sockets with protective and neutral
conductors!
Use only the extension cables or adapters that the manufacturer has approved for the
product!
Any use beyond what is listed here is prohibited!
Requirements for the target group
Only qualified personnel may work with this product!
In this operating manual, qualified personnel is defined as personnel meeting the following
requirements:
•
Personnel have received comprehensive training on working with electric vehicles.
•
Personnel have received training on working with all charging modes, in particular
mode 4.
•
Personnel must not be under the influence of medication or drugs while using the
equipment!