SECTION 4
INSTALLATION
Horizontal flue terminals and accessories
Part No.
Description
Min-Max length
0225720
0225755
0225740
0225745
0225750
0225730
0225735
0225760
Horizontal flue kit for use with
add. bends & extensions
Telescopic extension
0.5 m extension
1.0 m extension
2.0 m extension
45° bend (pair)
90° bend
Wall bracket (5)
1000 mm
350 mm-500 mm
500 mm
1000 mm
2000 mm
N/A
N/A
N/A
Fig. 7
Horizontal
terminal or
extension
Boiler
Outer
clamp
Push-fit
connection
Bend
Reduction in maximum flue length for each
bend
45° bend
90° bend
0.5 metre
1.0 metre
Reduction for additional bends
4.1
DELIVERY
Due to the weight of the appliance it may be
necessary for two people to lift and attach the
appliance to its mounting. The appliance is con-
tained within a heavy-duty cardboard carton. Lay
the carton on the floor with the writing the correct
way up.
4.2
CONTENTS
Contained within the carton is:
●
the boiler;
●
the wall bracket;
●
template;
●
an accessories pack containing appliance serv-
ice connections and washers;
●
the instruction pack containing the installation &
servicing instructions, user instructions, guar-
antee registration card, and a 3-amp fuse.
4.3
UNPACKING
At the top of the carton pull both sides open - do
not use a knife - unfold the rest of the carton from
around the appliance, carefully remove all protec-
tive packaging from the appliance, and lay the
accessories etc. to one sidee. Protective gloves
should be used to lift the appliance, the appliance
back-frame should be used for lifting points.
4.4
PREPARATION FOR MOUNTING THE APPLI-
ANCE
The appliance should be mounted on a smooth,
vertical, non-combustible surface, which must be
capable of supporting the full weight of the appli-
ance. Care should be exercised when determining
the position of the appliance with respect to hidden
obstructions such as pipes, cables, etc.
When the position of the appliance has been
decided - using the template supplied - carefully
mark the position of the wall- mounting bracket
(see fig. 6) and flue-hole (if applicable).
4.5
FITTING THE FLUE
The top flue outlet permits both horizontal and
vertical flue applications to be considered, alterna-
tively, the Vokera twin flue system can be utilised
if longer flue runs are required.
4.5.1
CONCENTRIC HORIZONTAL FLUE
(For concentric vertical flue, see 4.5.2).
(For twin flue applications, see 4.5.3).
The appliance can be used with either the Vokera
condensing 60/100mm concentric flue system or
the optional 80/125mm concentric flue system.
NOTE
These instructions relate
only
to the Vokera
condensing 60/100mm concentric flue system.
For specific details on the installation of the 80/
125mm concentric flue system please refer to the
instructions supplied.
The appliance flue outlet elbow can be rotated
through 360º on its vertical axis. In addition the
flue may be extended from the outlet elbow in the
horizontal plane (see 2.9). A reduction must also
be made to the maximum length (see table below)
when additional bends are used.
Using the template provided, mark and drill a
125mm hole for the passage of the flue pipe. The
hole should be drilled level to ensure any con-
dense fluid that forms, is allowed to drain back to
the appliance.
The fixing holes for the wall-mounting bracket
should now be drilled and plugged, an appropriate
type and quantity of fixing should be used to
ensure that the bracket is mounted securely.
Once the bracket has been secured to the wall,
mount the appliance onto the bracket.
FITTING THE HORIZONTAL FLUE KIT
Carefully measure the distance from the centre
of the appliance flue outlet to the edge of the fin-
ished outside wall (dimension
X
). Add 45mm to
dimension
X
to give you dimension
Y
(see fig 7A).
Measure dimension
Y
from the terminal end of
the concentric flue pipe and cut off the excess
ensuring any burrs are removed. Pass the con-
centric flue pipe through the previously drilled hole.
Fit the flue bend to the boiler flue outlet and insert
the concentric flue pipe into the flue bend ensur-
ing the correct seal is made.