13

4.5.2 CONCENTRIC VERTICAL FLUE

The appliance can be used with either the Vokèra 60/100mm
concentric Uni-flue system or the optional Vokera twin flue
system.

Fig.11

EXTENDING THE FLUE

The horizontal flue system can be extended using bends and/
or extensions from the Uni-Flue range (see 4.5.1).
Connect the bend – supplied with the terminal kit – to the top
of the boiler using the clips, screws, & gaskets supplied. The
additional bends & extensions have an internal push-fit
connection, care should be taken to ensure that the correct seal
is made when assembling the flue system. Connect the required
number of flue extensions or bends (up to the maximum
equivalent flue length) to the flue terminal using the clips,
screws, & gaskets supplied (see fig.10 & 12). The interior trim
should be fitted at this point.

NOTE

When cutting an extension to the required length, you must
ensure that the excess is cut from the plain end of the extension,
and that the inner (60mm) pipe is 7.5mm longer than outer
(100mm) pipe. Remove any burrs, and check that any seals are
located properly.
You must ensure that the entire flue system is properly supported
and connected.
Seal the flue assembly to the wall using cement or a suitable
alternative that will provide satisfactory weatherproofing. The
exterior trim can now be fitted.

FITTING THE HORIZONTAL FLUE KIT

Carefully measure the distance from the centre of the appliance
flue outlet to the face of the outside wall (dimension ‘X’). Ensure
the inner (60mm) pipe is fully inserted into the outer (100mm)
pipe (when the inner pipe is fully inserted, it stands proud of the
outer pipe by 7.5mm). Add 32mm to dimension ‘X’ to give the
overall flue length (dimension ‘Y’).

NOTE

The standard horizontal flue kit (part no. 2359029) is suitable
for a distance (dimension ‘Y’) of up to 865mm.
The telescopic flue kit (part no. 2359119) is suitable for a
distance (dimension ’Y’) of up to 600mm.
Dimension ‘Y’ is measured from the end of the terminal to the
end of the outer (100mm) pipe. The internal trim should be fitted
to the flue pipe before connection of the 90° bend.

Fig. 12

Total flue length 60-100

Restrictor  required

Up to 1.85 metre

42 mm diameter

From 1.85 to 3.35 metre

44 mm diameter

From 3.35 to 5.25 metre

Not installed

NOTE

These instructions relate 

only 

to the Vokèra 60/100mm

concentric flue system. For specific details on the installation
of the Vokera twin flue system please refer to the instructions
supplied. The vertical flue terminal can be connected directly
to the appliance flue outlet. Alternatively, an extension or bend
can be connected to the appliance flue outlet if desired,
however if additional bends are fitted, a reduction must be
made to the maximum flue length (see table below).

Reduction for bends

 

 Bend

Reduction in maximum flue length for each
bend

  45º bend

1 metre (60/100)

  90º bend

    1.5 metre (60/100)

Vertical flue terminal and accessories

  

Part No.

Description

Length

2359039

Vertical flue terminal

1.0 metre

531

Pitched roof flashing plate

N/A

532

Flat roof flashing plate

N/A

2359069

750 mm extension

750 mm

2359079

1500 mm extension

1500 mm

2359049

45º bend (pair)

N/A

2359059

90º bend

N/A

529

Wall bracket (5)

N/A

Using the dimensions given in fig. 12 as a reference, mark and
cut a 125mm hole in the ceiling and/or roof.

Fit the appropriate flashing
plate to the roof and insert the
vertical flue terminal through
the flashing plate from the
outside, ensuring that the
collar on the flue terminal fits
over the flashing.
The fixing holes for the wall-
mounting bracket should now
be drilled and plugged, an
‘appropriate type and quantity
of fixing should be used to
ensure that the bracket is
mounted securely. Once the
bracket has been secured to
the wall, mount the appliance
onto the bracket.

IMPORTANT

The vertical flue terminal is 1.0 metre in length and cannot be
cut; therefore it may be necessary to adjust the height of the
appliance to suit or use a suitable extension.
Connect the vertical flue assembly to the boiler flue spigot using
the 100mm clip, gasket & screws (supplied), ensuring the
correct seal is made. The flue support bracket (supplied with the
vertical flue kit) can now be fitted.
If the vertical flue requires extension/s or additional bend/s,
connect the required number of flue extensions or bends (up

130mm

Fig. 13

Содержание Compact 24 SE

Страница 1: ...INSTRUCTIONS TO BE RETAINED BY USER Vok ra is a licensed member of the Benchmark scheme which aims to improve the standards of installation and commissioning of domestic hot water systems in the UK C...

Страница 2: ...4 Flue system 10 3A 5 Air supply 11 3A 6 Water circulation 11 3A 7 Electrical supply 11 3A 8 Mounting on a combustible surface 11 3A 9 Timber framed buildings 11 3A 10 Inhibitors 11 3A 11 Showers 11...

Страница 3: ...r Vok ra Compact SE boiler has been designed to meet and exceed the very latest standards in gas central heating technology and if cared for will give years of reliable use and efficiency Please there...

Страница 4: ...ounter clockwise to reduce the temperature range 37 C 60 C Boiler at OFF standby Select this position when you want the boiler to be switched off for short periods days or if the boiler requires to be...

Страница 5: ...ppliance fails to ignite during the ignition sequence it will enter a lockout condition Should this occur please allow a period of at least two minutes before re setting the appliance 2 6 EXPLANATION...

Страница 6: ...f you think your boiler may have developed a fault please contact your installer or Vok ra Customer Services 0844 3910999 UK or 056 7755057 ROI have all your details to hand including full address and...

Страница 7: ...a sealed system only consequently they are not intended for use on open vented systems This booklet is an integral part of the appliance It is therefore necessary to ensure that the booklet is handed...

Страница 8: ...e minute anti cycle timer delay When the request for heat has been satisfied the appliance pump and fan may continue to operate to dissipate any residual heat within the appliance 1 4 MODE OF OPERATIO...

Страница 9: ...ht mm 715 Width mm 405 Depth mm 248 Dry weight kg 28 2 6 Clearances Compact 24 SE Sides 12mm Top 150mm from casing or 25mm above flue elbow whichever is applicable Bottom 150mm Front 500mm 2 7 Connect...

Страница 10: ...from a terminal on the same wall 300 mm P From a structure to the side of the vertical terminal 300 mm Q From the top of the vertical terminal to the roof flashing As determined by the fixed collar of...

Страница 11: ...to which BS 5440 PART 1 FLUES BS 5440 PART 2 FLUES VENTILATION BS 5449 PART 1 FORCED CIRCULATION HOT WATER SYSTEMS BS 5546 INSTALLATION OF GAS HOT WATER SUPPLIES FOR DOMESTIC PURPOSES BS 6798 INSTALLA...

Страница 12: ...1363 is acceptable 3 8 MOUNTING ON A COMBUSTIBLE SURFACE If the appliance is to be fitted on a wall of combustible material a sheet of fireproof material must protect the wall 3 9 TIMBER FRAMED BUILD...

Страница 13: ...SEALED SYSTEM An alternative method of filling the system would be from an independent make up vessel or tank mounted in a position at least 1 metre above the highest point in the system and at least...

Страница 14: ...flue applications to be considered alternatively the Vok ra twin flue system can be utilised if longer flue runs are required 4 5 2 CONCENTRIC HORIZONTAL FLUE For concentric vertical flue see 4 5 2 Fo...

Страница 15: ...ion of the 90 bend Fig 12 Total flue length 60 100 Restrictor required Up to 1 85 metre 42 mm diameter From 1 85 to 3 35 metre 44 mm diameter From 3 35 to 5 25 metre Not installed NOTE These instructi...

Страница 16: ...rough the ceiling and or roof Depending on site conditions it may be preferable to install the terminal assembly prior to fitting the twin flue pipes Fit the appropriate flashing plate to the roof and...

Страница 17: ...2mm pipe to the inlet of each valve and tighten both nuts NOTE Depending on system requirements it may necessary to increase the size of the flow return pipe work after the service valve connections 4...

Страница 18: ...ed as outlined below locate and unscrew the 2 screws A that secure the outer casing to the appliance lift the casing upward to disengage it from the top locating hooks and then remove store the casing...

Страница 19: ...e gas rate then a combustion analysis test must be carried out in accordance with BS 7967 UK to ensure the appliance is left working safely and correctly Additionally if the gas valve has been adjuste...

Страница 20: ...these instructions and explain the importance of keeping them in a safe place Explain to the user how to isolate the appliance from the gas water and electricity supplies and the locations of all drai...

Страница 21: ...cking pin I from the pump assembly and remove the AAV assembly J Replace in the reverse order 6 8 WATER PRESSURE SWITCH fig 24 Carry out component removal procedure as described in 6 4 Locate and remo...

Страница 22: ...the inner combustion cover and remove Disconnect the spark plug cable connection slide off the lower cable grommet from the seat of the air distribution box remove the burner fixing screws and remove...

Страница 23: ...t the cold water inlet pipe at the DHW flow switch B2 Using a small screwdriver gently ease the flow restrictor C2 from its seating Replace in the reverse order Ensure all seals are in good condition...

Страница 24: ...minutes timer delay When a new ignition sequence begins the output of the appliance is set at minimum for two minutes NOTE Any demand for hot water has the priority If there is a demand for hot water...

Страница 25: ...umper JP2 turn the domestic hot water temperature adjustment knob C until it reaches the heating maximum value as indicated in the multigas table remove the jumper JP2 to store the heating maximum val...

Страница 26: ...sing cycle the temperature value is restored to the value set by the user and the above mentioned cycle is repeated until the ambient thermostat request is fulfilled Fixed green if there is flame the...

Страница 27: ...uminated See table on page 4 7 7 5 RESISTANCE TO EARTH CHECK Isolate the appliance from the electrical supply and using a suitable multi meter carry out a resistance test Connect test leads between th...

Страница 28: ...4 VOK RA LOWER COVER MECHANICAL CLOCK fig 3 The Vok ra lower cover mechanical clock kit product code 20025081 is entirely suitable for the Compact 24SE and eliminates the need for an external time co...

Страница 29: ...d LED Led 1 green working status or temporary stop Led 2 Not installed Led 3 red boiler lock out F1 Fuse 2A T F External fuse 3 15A F M3 Terminal strip for electrical connection hight power P Pump OPE...

Страница 30: ...circuit board MP08 20005569 21 Led light guide 20013352 26 Control panel 20035608 27 Knob 20013055 31 Case Assembly 20026073 34 Fixing flange 20023928 90 Fuse R3478 470 Ignition transformer TR6 R1002...

Страница 31: ...w actuator R10022349 27 Heating cock R1789 28 Connection R1790 30 Water supply stop cock R7099 36 Pipe 20005557 48 Cock 20000533 63 Pipe 20035609 201 Washer R5026 265 Washer R5236 266 Washer R5237 288...

Страница 32: ...20029826 2 Pipe R10028603 3 Pump R10027571 4 Air vent bottle R10025485 7 Pipe 20005559 8 Heat exchanger 20005544 9 Pipe 20005558 200 Washer R5023 290 Clip R2165 299 Washer R10022726 302 Washer R5025...

Страница 33: ...551 5 Spark ignition electrode R10025985 12 Gas pipe 20005554 13 Gas valve 20035533 14 Gas pipe 20005553 15 3 4 gas cock R10020897 16 Combustion chamber cover 20005594 17 Gas valve solenoid R10020838...

Страница 34: ...ation panel 20005560 7 Flue draught diverter 20005596 10 Fan kit 20026724 11 Pressure connection 20021548 12 Fumes connection 20011048 13 Segnal amplifier 20025687 17 Washer 20005552 22 Flange 42 R100...

Страница 35: ...ution box over and combustion chamber cover fig 22 disconnect the spark plug cable connection slide off the lower cable grommet from the seat of the air distribution box remove the burner fixing screw...

Страница 36: ...ALL INSTALLATIONS If required by the manufacturer record the following CO2 OR CO ppm OR CO CO 2 Ratio The heating and hot water system complies with the appropriate Building Regulations Yes The boile...

Страница 37: ...ignature SERVICE 7 Date Energy Efficiency Checklist completed Yes No Engineer Name Company Name Telephone Number CORGI ID Number Comments Signature SERVICE 9 Date Energy Efficiency Checklist completed...

Страница 38: ......

Страница 39: ......

Страница 40: ...s vokera co uk www vokera co uk www vokera ie Sales General Enquires T 0844 391 0999 F 0844 391 0998 Vok ra Ireland West Court Callan Co Kilkenny T 056 7755057 F 056 7755060 Vok ra Limited reserve the...

Отзывы: