Line Voltage Limiter Adjustment
The LINE VOLTAGE LIMITER adjustment is factory preset for maximum output. To limit the output voltage adjust
the controller using the procedure below.
1. Connect a voltmeter to any two of the output terminals of the controller, (T1, T2, T3).
2. Turn power on and wait at least one minute to allow the soft start circuit to bring the output up to line voltage.
3. To lower the output voltage of the controller, rotate the LINE VOLTAGE LIMITER adjustment toward 0 (CCW).
Continue to rotate the adjustment until the measured voltage output of the controller matches the motor nameplate
voltage, The Line Voltage Limiter must not be adjusted below the motor nameplate voltage.
NOTE: The Line Voltage Limiter adjustment can reduce the motor terminal voltage to a level not less than the value of
voltage determined by the START TORQUE adjustment. If unable to lower the output voltage, reduce the START
TORQUE until an acceptable output is obtained.
Dual Ramp and Energy Saving Controls
The soft starter has provisions for dual ramp soft starting, however, this feature is not used on a Tube-Ice machine. The
soft starter also has a energy saving power factor correction feature which is not employed on the Tube-Ice machine.
Energy savings can only be obtained when a motor is running at less than 50% of it’s full load amps. The power factor
correction adjustment should be set for maximum output.
Wiring
The soft starter should be wired in series between the compressor motor contactor and the compressor. A jumper should
be installed between the controller terminals marked “RAMP 1” and “COMMON”.
Figure 10-5
Soft Starter, Wiring Schematic
Содержание TUBE-ICE P-118F
Страница 1: ...P 118F TUBE ICE MACHINE Service Manual 5000 1 6 09 ...
Страница 4: ......
Страница 6: ......
Страница 14: ...P118F Service Manual INTRODUCTION 1 6 09 1 4 FIGURE 1 1 Assembly Air Cooled Front View ...
Страница 15: ...P118F Service Manual INTRODUCTION 1 6 09 1 5 FIGURE 1 2 Assembly Air Cooled Rear View ...
Страница 16: ...P118F Service Manual INTRODUCTION 1 6 09 1 6 FIGURE 1 3 Assembly Air Cooled Right Side View ...
Страница 17: ...P118F Service Manual INTRODUCTION 1 6 09 1 7 FIGURE 1 4 Assembly Water Cooled Front View ...
Страница 18: ...P118F Service Manual INTRODUCTION 1 6 09 1 8 FIGURE 1 5 Assembly Water Cooled Rear View ...
Страница 19: ...P118F Service Manual INTRODUCTION 1 6 09 1 9 FIGURE 1 6 Assembly Water Cooled Right Side View ...
Страница 20: ...P118F Service Manual INTRODUCTION 1 6 09 1 10 ...
Страница 23: ...P118F Service Manual RECEIPT OF YOUR TUBE ICE MACHINE 1 6 09 2 3 ...
Страница 25: ...P118F Service Manual INSTALLING YOUR TUBE ICE MACHINE 1 6 09 3 2 FIGURE 3 1 Space Diagram Water Cooled Machine ...
Страница 26: ...P118F Service Manual INSTALLING YOUR TUBE ICE MACHINE 1 6 09 3 3 FIGURE 3 2 Space Diagram Air Cooled Machine ...
Страница 37: ......
Страница 38: ...1 6 09 ...
Страница 41: ...P118F Service Manual HOW YOUR TUBE ICE MACHINE WORKS 1 6 2009 3 FIGURE 4 1 Water Cooled Piping Schematic ...
Страница 42: ...P118F Service Manual HOW YOUR TUBE ICE MACHINE WORKS 1 6 2009 4 FIGURE 4 2 Air Cooled Piping Schematic ...
Страница 48: ......
Страница 49: ...1 6 09 ...
Страница 52: ...P118F Service Manual ELECTRICAL CONTROLS 1 6 09 6 3 FIGURE 6 2 Electrical Schematic All Voltages 50 60 Hz ...
Страница 88: ...P118F Service Manual SERVICE OPERATIONS 1 6 09 9 18 FIGURE 9 8 Cutter Water Tank Assembly ...
Страница 89: ...P118F Service Manual SERVICE OPERATIONS 1 6 09 9 19 FIGURE 9 9 Cutter Tank Parts cylinder ice ...
Страница 90: ...P118F Service Manual SERVICE OPERATIONS 1 6 09 9 20 FIGURE 9 10 Cutter Drive Parts ...
Страница 91: ...P118F Service Manual SERVICE OPERATIONS 1 6 09 9 21 FIGURE 9 11 Cutter Tank Parts crushed ice option ...
Страница 102: ...P118F Service Manual TABLES CHARTS 1 6 09 11 1 11 Tables Charts ...
Страница 111: ...P118F Service Manual TABLES CHARTS 1 6 09 11 10 ...
Страница 115: ...P118F Service Manual INDEX 1 6 09 12 4 ...