P118F Service Manual
TABLES & CHARTS
1/6/09
11-2
P118F SPECIFICATIONS, 208-230 Volt-3 Phase- 60Hz
Tube Size
inches
(cm)
1
(2.54)
1 1/4
(3.17)
1 1/2
(3.18)
Nominal Capacity
(1)
lbs/day
(Kg/day)
10,400
(4,717)
9,800
(4,445)
9,700
(4,400)
Overall Dimensions (LxWxH)
inches
(meters)
60 x 32 x 84
(1.5x0.81x2.1)
60 x 32 x 84
(1.5x0.81x2.1)
60 x 32 x 84
(1.5x0.81x2.1)
Shipping Weight
lbs
(Kg)
3200
(1452)
3200
(1452)
3200
(1452)
Operating Weight
lbs
(Kg)
2975
(1349)
2975
(1349)
2975
(1349)
Refrigerant Charge (HCFC-22)
lbs
(Kg)
260
(118)
260
(118)
260
(118)
Total FLA Water Cooled
(2)
82.3 82.3 82.3
Total FLA Air Cooled
(2)
73.3 73.3 73.3
Maximum Fuse
WC / AC
120/130 120/130 120/130
Minimum Ampacity
WC / AC
68/77 68/77 68/77
Water Requirements
-makeup
(3)
gpm
(m
3
/ Hr)
1.2
(0.27)
1.2
(0.27)
1.2
(0.27)
-condenser
(4)
gpm
(m
3
/ Hr)
37
(8.40)
37
(8.40)
37
(8.40)
Connection Sizes
-makeup water
FPT
3/4” ¾” 3/4”
-tank drain
FPT
1” 1” 1”
-condenser water inlet
FPT
1 1/4”
1 1/4”
1 1/4”
-condenser water outlet
MPT
1 1/4”
1 1/4”
1 1/4”
-AC condenser inlet
ODC
1 5/8”
1 5/8”
1 5/8”
-AC condenser outlet
ODC
1 1/8”
1 1/8”
1 1/8”
Compressor -HP/KW/FLA
15/11.2/59.6 15/11.2/59.6 15/11.2/59.6
Water Pump -HP/KW/FLA
1.5 / 1.9 / 4.8
1.5 / 1.9 / 4.8
1.5 / 1.9 / 4.8
Cutter Motor -HP/KW/FLA
0.5 / 0.7 / 2.2
0.5 / 0.7 / 2.2
0.5 / 0.7 / 2.2
THR
Btu/hr
(kW)
170,000
(49.8)
170,000
(49.8)
170,000
(49.8)
Marley Cooling Tower
(5)
4821 4821 4821
-dimensions (LxWxH)
ft
(meters)
5x 4 x 6.5
(1.5x1.2x2.0)
5x 4 x 6.5
(1.5x1.2x2.0)
5x 4 x 6.5
(1.5x1.2x2.0)
-shipping weight
lbs
(Kg)
740
(336)
740
(336)
740
(336)
-operating weight
lbs
(Kg)
1340
(
608)
1340
(
608)
1340
(
608)
-fan (HP/KW/FLA)
1 / 0.8 / 3.6
1 / 0.8 / 3.6
1 / 0.8 / 3.6
Tower Pump
-flow
gpm
(m
3
/Hr)
78
(17.7)
78
(17.7)
78
(17.7)
-TDH
minimum
ft
(m)
80
(24.4)
80
(24.4)
80
(24.4)
-HP/KW/FLA
3 /2.2 / 9.6
3 /2.2 / 9.6
3 /2.2 / 9.6
-connections (inlet x outlet)
FPT
1.5” x 1”
1.5” x 1”
1.5” x 1”
-shipping weight
lbs
(Kg)
65
(29.5)
65
(29.5)
65
(29.5)
Kramer Air-Cooled Condenser
(6)
DD-311 DD-311 DD-311
- # of Fans / HP
5 / 0.5
5 / 0.5
5 / 0.5
-total KW/FLA
2.8/ 9.0
2.8 / 9.0
2.8 / 9.0
-inlet connection
ODC
1 5/8”
1 5/8”
1 5/8”
-outlet connection
ODC
1 1/8”
1 1/8”
1 1/8”
-shipping weight
lbs
(Kg)
610
(277)
610
(277)
610
(277)
-operating weight
lbs
(Kg)
660
(299)
660
(299)
660
(299)
(1) Nominal capacity is based on 70°F makeup water, 100°F condensing temperature, 70°F ambient, and 0% blowdown.
(2) FLA for 460 volt models is approximately 1/2 that of 230 volt models. Total FLA does not include cooling tower.
(3) Makeup water is maximum value and includes 10 gallons per cycle blowdown.
(4) Condenser flow rate is for 85°F entering water temperature and 100°F condensing.
(5) Tower sized for 85°F wet bulb temperature.
(6) Recommended air-cooled condenser is based on 15°F TD.
Vogt reserves the right to change designs and specifications without notice.
Table 11-1
Содержание TUBE-ICE P-118F
Страница 1: ...P 118F TUBE ICE MACHINE Service Manual 5000 1 6 09 ...
Страница 4: ......
Страница 6: ......
Страница 14: ...P118F Service Manual INTRODUCTION 1 6 09 1 4 FIGURE 1 1 Assembly Air Cooled Front View ...
Страница 15: ...P118F Service Manual INTRODUCTION 1 6 09 1 5 FIGURE 1 2 Assembly Air Cooled Rear View ...
Страница 16: ...P118F Service Manual INTRODUCTION 1 6 09 1 6 FIGURE 1 3 Assembly Air Cooled Right Side View ...
Страница 17: ...P118F Service Manual INTRODUCTION 1 6 09 1 7 FIGURE 1 4 Assembly Water Cooled Front View ...
Страница 18: ...P118F Service Manual INTRODUCTION 1 6 09 1 8 FIGURE 1 5 Assembly Water Cooled Rear View ...
Страница 19: ...P118F Service Manual INTRODUCTION 1 6 09 1 9 FIGURE 1 6 Assembly Water Cooled Right Side View ...
Страница 20: ...P118F Service Manual INTRODUCTION 1 6 09 1 10 ...
Страница 23: ...P118F Service Manual RECEIPT OF YOUR TUBE ICE MACHINE 1 6 09 2 3 ...
Страница 25: ...P118F Service Manual INSTALLING YOUR TUBE ICE MACHINE 1 6 09 3 2 FIGURE 3 1 Space Diagram Water Cooled Machine ...
Страница 26: ...P118F Service Manual INSTALLING YOUR TUBE ICE MACHINE 1 6 09 3 3 FIGURE 3 2 Space Diagram Air Cooled Machine ...
Страница 37: ......
Страница 38: ...1 6 09 ...
Страница 41: ...P118F Service Manual HOW YOUR TUBE ICE MACHINE WORKS 1 6 2009 3 FIGURE 4 1 Water Cooled Piping Schematic ...
Страница 42: ...P118F Service Manual HOW YOUR TUBE ICE MACHINE WORKS 1 6 2009 4 FIGURE 4 2 Air Cooled Piping Schematic ...
Страница 48: ......
Страница 49: ...1 6 09 ...
Страница 52: ...P118F Service Manual ELECTRICAL CONTROLS 1 6 09 6 3 FIGURE 6 2 Electrical Schematic All Voltages 50 60 Hz ...
Страница 88: ...P118F Service Manual SERVICE OPERATIONS 1 6 09 9 18 FIGURE 9 8 Cutter Water Tank Assembly ...
Страница 89: ...P118F Service Manual SERVICE OPERATIONS 1 6 09 9 19 FIGURE 9 9 Cutter Tank Parts cylinder ice ...
Страница 90: ...P118F Service Manual SERVICE OPERATIONS 1 6 09 9 20 FIGURE 9 10 Cutter Drive Parts ...
Страница 91: ...P118F Service Manual SERVICE OPERATIONS 1 6 09 9 21 FIGURE 9 11 Cutter Tank Parts crushed ice option ...
Страница 102: ...P118F Service Manual TABLES CHARTS 1 6 09 11 1 11 Tables Charts ...
Страница 111: ...P118F Service Manual TABLES CHARTS 1 6 09 11 10 ...
Страница 115: ...P118F Service Manual INDEX 1 6 09 12 4 ...