9-12
Circulating Water Pump Motor
The motor bearings are pre-lubricated and sealed. They require no further lubrication. The pump should operate
with the water level above the impeller housing. The pump also has a mechanical seal that requires no
lubrication and is self-adjusting. However, the pump should not be operated unless it is circulating water. The
pump manufacturer recommends that a mechanical seal be kept as a spare. When ordering a seal, specify pump
size, type, serial number, and manufacturer’s name as indicated on the nameplate.
Figure 38: Circulating Water Pump
Table 13 shows replacement part numbers for the water pump and seal kit:
Table 13: Circulating Water Pump Parts
Part Description
Vogt Part Number
Water Pump Seal Kit
12A4080S12
Water Pump, 60 Hz
12A4020G01
Water Pump, 50 Hz
12A4020G08
Cutter Gear Reducer
The oil level for the gear reducer should be level with the plugged opening in the side of the gear housing. If not,
this is evidence of a leak. Use food-grade oil and change oil once a year. The motor bearings are pre-lubricated
and require no further lubrication.
Figure 39: Gear Reducer
Table 14 shows replacement part numbers for the gear reducer and lubricating oil:
Gear Reducer (10:1)
Part #: 12A4030R12
Replacement Food-Grade Oil:
•
Part #: 19T3020C01
•
Texaco Cygnus 220
•
Oil Capacity: 8 oz (227 g)
Vent Plug
Drain Plug
Oil Level Plug
Vent Plug
Pump Suction (2-in. [DN 50] FPT)
Pump Discharge (1-1/2-in. [DN 40] FPT)
Содержание Tube-Ice HFO10
Страница 2: ......
Страница 6: ......
Страница 10: ......
Страница 12: ......
Страница 16: ...2 4 Figure 3 Water Cooled Piping Schematic ...
Страница 17: ...2 5 Figure 4 Air Cooled Piping Schematic ...
Страница 36: ......
Страница 40: ......
Страница 43: ...6 3 Figure 16 Panel Layout 60 Hz Non CE Machines ...
Страница 44: ...6 4 Figure 17 Electrical Schematic Control Circuit All Voltages 50 Hz ...
Страница 45: ...6 5 Figure 18 Electrical Schematic Control Circuit All Voltages 60 Hz ...
Страница 46: ...6 6 Figure 19 Electrical Schematic 3 Phase Power All Voltages 50 Hz ...
Страница 47: ...6 7 Figure 20 Electrical Schematic 3 Phase Power All Voltages 60 Hz ...
Страница 68: ......
Страница 96: ......
Страница 110: ...Notes ...
Страница 111: ...Notes ...