7-4
CPU/Power LED
Table 7-3: Erratic Key Telephone Operation
SYMPTOM
DIAGNOSTIC AID
CAUSE
CORRECTIVE ACTION
Erratic operation:
LCD Display and
LEDs
Faint data noise
during background
conversation
Digital Volt/OHM
meter
Cable distance is too
long for gauge of
cable used.
Non-standard
telephone cable
being used or
multiple digital
stations fed from
one common cable.
If a key telephone is not receiving clear
2B+D signal from KSU, test as follows:
Test cable with a known good keyset.
Check wiring, cables, and connectors.
Replace card.
Check AC voltage.
Table 7-4: Key Telephone (cannot be heard)
SYMPTOM
DIAGNOSTIC AID
CAUSE
CORRECTIVE ACTION
Other party cannot
hear you. (handset)
Key Telephone
(other station)
Component failure
1. Verify MUTE Btn LED is not lit.
2 Lift handset, dial another station. Talk.
3 Replace handset assembly and repeat
Step 1.
4 Replace handset cord and repeat
Step 1.
5 If still no transmit, the key telephone
will need to be replaced.
Содержание Starplus DHS
Страница 2: ...FEATURE PACKAGE 3 STARPLUS DHS and DHS E Technical Manual Issue 2 March 2000 Part Number SP7050 03...
Страница 17: ......
Страница 21: ...1 4 Toll Fraud and DISA Disclaimer...
Страница 23: ......
Страница 79: ...2 56 Feature Upgrade Procedure...
Страница 81: ......
Страница 121: ......
Страница 227: ......
Страница 249: ......
Страница 293: ......
Страница 303: ......
Страница 326: ...B Part Numbers...
Страница 327: ......
Страница 329: ...B 2...
Страница 337: ...xx January 2000 Index...
Страница 338: ...www vodavi com 2000 Vodavi Technology Inc Vodavi is a registered trademark of Vodavi Technology Inc SP7050 03...