38
ERROR MESSAGE TABLE
Error
Code
Error Message Displayed
Cause
5
COMP TEMP SENSOR
FAILED
–
OPEN
Temperature sensor on the compressor is
unplugged or wire to control box has been cut.
6
COMP TEMP SENSOR
FAILED
–
SHORT
Temperature sensor on the compressor is
shorted.
7
COMP TOO COLD
xx.x
F/xx.x
C
Compressor is too cold to start. The
temperature is displayed.
8
COMP OVER TEMP
xx.x
F/xx.x
C
Compressor is too hot to start. The
temperature is displayed.
9
MANIFOLD TEMP
FAILED
–
OPEN
Temperature sensor on the manifold is
unplugged or wire to control box has been cut.
10
MANIFOLD TEMP
FAILED
–
SHORT
Temperature sensor on the manifold is
shorted.
11
MANIFOLD ERROR
CHECK COALESCER
The coalescer should be checked. There is a
possibility of a plug.
12
AIR PRESS SIGNAL
VOLTAGE LOW
Low voltage reading on the air pressure
transducer.
13
AIR PRESS SIGNAL
VOLTAGE HIGH
Over voltage reading on the air pressure
transducer.
14
AIR PRESS SENSOR
TOO HIGH
Air pressure is too high to start the engine.
AIR PRESSURE
xxx.x PSI
If the previous error is present the air pressure
is displayed.
34
ENGINE RPM
NOT DETECTED
Engine RPM is not detected. Wire may be cut,
tach sensor on bell-housing may be loose or
fuel problem caused engine to stop suddenly.
35
ENGINE CRANK
TIME OUT
The engine did not start during the crank
cycle.
36
ENGINE OIL LOW
Oil level in the diesel engine is low.
37
ENGINE TEMP
PROBE OPEN
Temperature sensor on the diesel engine is
unplugged or wire to control box has been cut.
38
ENGINE TEMP
PROBE SHORT
Temperature sensor on the diesel engine is
shorted.
39
ENGINE TEMP TOO
COLD TO START
The diesel engine is too cold to start.
40
ENGINE
OVER TEMP
The diesel engine is too hot to start.
41
SERVICE PANEL
OPEN
The service panel is open. It must be closed
before the unit is run.
42
FUEL LEVEL LOW
PLEASE RE-FILL
Fuel level for the diesel engine is low. It must
be re-filled before the unit is run.
27
UNEXPECTED
ENGINE OPERATION
Unexpected engine operation can have many
causes. It is likely due to RPM detected during
an OFF state.
-
DISPLAY CANBUS
CONN ERROR
A CAN bus error between the Display box and
Control box.
-
End of Errors
OK to Retry?
End of errors screen. Pressing ENTER will try
to restart the system.
52
ENGINE RPM
UNDERSPEED
Engine speed went below 2000RPM for 3
seconds.