VMAC
– Vehicle Mounted Air Compressors
Toll Free:
1-888-241-2289
Fax: 1-250-740-3201
26
Electrical Connections
External Electrical Connections
The Gas Drive runs on a 12 V system. If mounted on the stand-alone
base plate the Gas Drive will come with a battery. In this case no
electrical connections are required. However, if the Gas Drive is
removed from the stand-alone base plate external electrical connections
may be required.
If desired the Gas Drive can be wired into an external power supply and
the key switch can be relocated.
Battery relocation
Use appropriate gauge cable and ground wire to connect to battery
source (Table 2).
Battery wire connections cable length
(total length of power wire plus ground wire)
Suggested
Gauge
Less than 5 ft (1.5 m)
4 AWG
5 ft (1.5 m) to 8 ft (2.5 m)
2 AWG
8 ft (2.5 m) to 13 ft (4.5 m)
1 AWG
Table 2 - Battery extension gauge
Key switch relocation
If desired the key switch can be relocated away from the Gas Drive
engine.
Use appropriate gauge wire to extend the key switch (Table 3).
Key switch wire connection cable length
Suggested
Gauge
Less than 5 ft (1.5 m)
14 AWG
5 ft (1.5 m) to 8 ft (2.5 m)
12 AWG
8 ft (2.5 m) to 13 ft (4.5 m)
10 AWG
Table 3 - Key switch extension gauge
The supplied key switch is weather resistant. However,
the drain hole in the key switch housing must be mounted
facing down.
Electronic Fuel Pump
The use of an electronic fuel pump is not recommended or supported by
VMAC. Contact a Subaru Industrial Power Product dealer for information
regarding external fuel pumps.
Содержание RAPTAIR-G30
Страница 1: ...RAPTAIR G30 Gas Drive Air Compressor Installation Owner s and Service Manual G300002...
Страница 2: ......
Страница 89: ...This page intentionally left blank...
Страница 91: ...This page intentionally left blank...
Страница 92: ...This page intentionally left blank...
Страница 93: ...This page intentionally left blank...
Страница 94: ...This page intentionally left blank...
Страница 95: ......
Страница 96: ......