FEATURES

v
v
v
v
v
v
v
v
v
v
v
v
v
v
v

Colour 3 5

Non-volatile memory for 64 B/W images
Non-volatile clock
Operation with two doorstations and extra camera (commutator BKM-440 required)

Operation with one doorstation, door bell button and extra camera (commutator BKM-440 not required)
Calls from doorstation and door bell button
Duplex intercom
Remote door unlocking with the        button
Door zone video monitoring
Activation of individual / storey doorstation by subscriber (duplex intercom and video monitoring)

On-screen menu

4 ring tones, individual ring tone for each doorstation and door bell button.
3 ring volume levels
Individual image brightness, contrast and saturation for each doorstation and extra camera
LED indication of operating modes

. ” TFT LCD

INSTALLATION

www.

201 -1 )

VIZIT-M440CM Operating Instruction (revision

5 2

vizit-group.com

2 9

/

Figure

Installation order

3 -

2

Choose the position for monitor  Recommended altitude is 150 cm from the floor to the monitor center

.

.

4

Connect the handset to
the monitor.

1

3

2

85

57

85

1

Make 3 holes      in the wall.
Refer to page 25 for Mounting Pattern.
Drive in concrete inserts     and screws
supplied with your monitor.

3

2

1

Connect the wires to the terminals of your
monitor as shown in Fig. 4-7.
Match the monitor’s fixing lugs with the
screws in the wall, and hook the monitor
on the screws.

3

4

5

Remove a battery cover

.

Place a battery R

2

into

.

P

C 203

compartment

observing the polarity

lace the cover back.

5

4

Содержание VIZIT-M440CM

Страница 1: ...t by yourself Please refer all services to qualified service personnel www 201 1 VIZIT M440CM Operating Instruction revision 5 2 vizit group com 1 9 Figure Appearance and controls layout 1 1 7 3 9 2 4...

Страница 2: ...ual image brightness contrast and saturation for each doorstation and extra camera LED indication of operating modes TFT LCD INSTALLATION www 201 1 VIZIT M440CM Operating Instruction revision 5 2 vizi...

Страница 3: ...BKM 440 operating instruction If the monitor operates together with the commutator a door bell button connection is not available examples of wiring diagrams BKM 440 Note BKM 440 Terminal LN LN GND VI...

Страница 4: ...next commutators To other apartments 82 Ohm resistor should be connected between the VO and VG terminals of the last commutator in the circuit 440 MONITOR VIZIT M CM Extra Camera 12 V max 0 3 To doors...

Страница 5: ...VG V2 FB LN VG V3 FC LN VG V4 FD LN VG GND LINE SEL Ek VI 82 Ohm resistor should be connected between the VO and VG terminals of the last commutator in the circuit COMMUTATOR BK 4MV or BK 4V To doors...

Страница 6: ...OWER SUPPLY BPD18 12 1 1 Extra Monitor Main Monitor INDIVIDUAL STOREY DOORSTATION INDIVIDUAL STOREY DOORSTATION V 1A 50 ELECTROMECHANICAL LOCK R 10 OHM ELECTROMECHANICAL LOCK R 10 OHM V 1A 50 LN GND L...

Страница 7: ...ressing the and buttons one of four select in the menu Press the button and the cursor bar jumps to the current setting Press or to select a new ring tone Every time you press either or the selected r...

Страница 8: ...ressing the door bell button the monitor rings image from the extra camera appears on the screen see Fig 4 5 To engage the sleep mode press and hold until the Power LED turns off The monitor can be co...

Страница 9: ...Video IN impedance voltage Operating voltage Power consumption max Dimensions W x H x D x x Weight TFT LCD PAL 470 1 1 8 15 27 3 0 183 48 Ambient temperature range to Relative humidity of air up to at...

Отзывы: