15
14
Operating manual Omni-Flow
Edition 1.0. 09/2017
10 / 32
Operating panel
5.3
Operating panel
: O
perating panel and emergency STOP
LED green "ON"
- Flashing: Machine is ready.
- Lit: Processing active.
LED red "STOP"
Lit:
- The unit is calibrating.
- Processing inactive.
- The cover is opened.
START button
- Switches on the motor.
- When
pressed briefly
, a single sheet
is fed into the machine for trial purposes.
- When
pressed longer than 2 seconds
, the
machine switches into automatic mode.
STOP button
Stops the machine.
UP button
- Raises the table.
- Can only be actuated when the
machine is not running and the STOP
button
lights up red.
DOWN button
- Lowers the table.
- Can only be actuated when the
machine is not running and the STOP
button
lights up red.
Emergency STOP
- Stops the machine immediately.
Touchscreen display
The main menu is displayed approx.
10 seconds after the machine has been
switched on. For information on
operation
:
Chapter 8:
operation and functions of the display.