To insure proper operation of the VM-480B Pipe and Cable Locator, use the checkout procedure 

at the following times:

•    Upon receiving the equipment
•    Before each job, preferably before you leave for the site
•    If problems arise during a locate

1.  Turn the transmitter on by pulling the PUSH/PULL POWER SWITCH and place the transmitter 

on the ground. If the batteries are working, the battery lamp will blink.

2.  Turn the receiver ON (if the batteries are working, the meter will move to the BATT section of 

the meter) and set to the Active/Norm Mode.

3.   Set the SENSITIVITY knob to the “SET” line.

4.  Hold the receiver in a position parallel to the transmitter. The meter needle should move all the 

way to the right side of the meter, and the audio tone should be loud.

5.  Move away from the transmitter, holding the receiver in the same parallel position. At 10-20ft 

the signal level should start to drop - the meter needle will move to the left and the audio tone 

will begin to fade.

6.  Turn the receiver perpendicular to the transmitter - both the meter reading and the audio tone 

should suddenly drop.

If either the receiver or the transmitter does not respond to the above tests, check the batteries. 

Refer to Section 7, Maintenance for instructions.

4.1 

To Check the 50/60Hz Power Mode

1 .   Test the receiver only (the transmitter is not required for passive locating). Stand under an 

indoor AC powered light future.

2 .    Set the range to “HIGH” and the sensitivity to the 12 o’clock position.

3 .  

Hold the receiver in a vertical position and raise the receiver upward toward the light fixture. The 
meter reading and audio tone should increase as the receiver gets closer to the light fixture.

If either the receiver or the transmitter does not respond to the above tests, check the batteries. 

Refer to Section 7, Maintenance for instructions.

NOTE

The VM-480B receiver features a 30-minute automatic shut-off to prevent 

the receiver from being accidentally left on. A beep will sound to alert the 

operator that the receiver is about to shut off. Reactivate the receiver by 

turning the RANGE KNOB back to “OFF” and then to “NORM” or “HIGH”.

4    Checkout Procedure

Checkout Procedure

[email protected] | 13309 Beach Ave. Marina del Rey, CA 90292 

wctproducts.com | Phone:  800-WCT-PROD (928-7763) | Fax: 310-306-9343

Содержание VM-480B

Страница 1: ...VM 480B User Handbook English Edition Version 1 3 P N 4 04 000029 info wctproducts com 13309 Beach Ave Marina del Rey CA 90292 wctproducts com Phone 800 WCT PROD 928 7763 Fax 310 306 9343...

Страница 2: ...info wctproducts com 13309 Beach Ave Marina del Rey CA 90292 wctproducts com Phone 800 WCT PROD 928 7763 Fax 310 306 9343...

Страница 3: ...1 To Start Locating 10 5 2 Direct Conductive Connection 11 5 2 1 Transmitter 11 5 2 2 Peak Method 12 5 2 3 Null Method 12 5 3 Inductive Coupling with the 4820 Metroclamp 13 5 4 Inductive Indirect Met...

Страница 4: ...d Conductors 22 6 11 CongestedAreas 22 6 12 Pipes with Insulated Junctions 22 6 13 Metroclamp Ground Requirements 23 6 14 Grounding Safety 23 6 15 Distribution Systems 23 Maintenance 24 7 1 Checking a...

Страница 5: ...connecting the cable from the transmitter Do NOT hold any uninsulated portion of the connection leads clips when the transmitter is switched on 1 4 Batteries and Environmental Safety Vivax Metrotech...

Страница 6: ...cated resulting in incorrect information Always locate responsibly and use information learned during your training to interpret the information provided by the locator Do NOT provide information rega...

Страница 7: ...pliant with relevant provision of European directive 1999 5 EC EN 55011 EN 61000 4 2 A1 A2 EN 61000 4 3 EN 61000 4 8 A1 1 General Safety Care Information info wctproducts com 13309 Beach Ave Marina de...

Страница 8: ...d software revision number when requesting product support They can be found as follows for reference only NOTE The transmitter Model Serial Number can be found on the receiver 2 Service Support Servi...

Страница 9: ...Herbert Iann Str 6 96148 Baunach Germany Tel 49 9544 680 Fax 49 9544 2273 Website www sebakmt com Email service sebakmt com Australasia China Vivax Metrotech AUS Unit 1 176 South Creek Road Cromer NS...

Страница 10: ...avels along the conductor becoming weaker as it gets farther away from the transmitter The distance that the signal travels before it becomes too weak to be detected depends on the method of connectio...

Страница 11: ...en it stops blinking replace the batteries COND AUX OUTPUT JACK Insert either the direct connect cable or the 4820 Metroclamp cable into this jack The transmitter s internal antenna is automatically d...

Страница 12: ...he targeted conductor MODE SWITCH Two operating positions Active Direct Connect Inductive coupling and inductive Passive For tracing energizing 50 60Hz power lines AUX INPUT Jack Plug in second 4820 M...

Страница 13: ...he meter reading and the audio tone should suddenly drop If either the receiver or the transmitter does not respond to the above tests check the batteries Refer to Section 7 Maintenance for instructio...

Страница 14: ...al through the conductor by inserting a snake or fish tape into the pipe and connecting the Direct Connect Cable from the transmitter to one end of it WARNING Never make a direct connection to a live...

Страница 15: ...t angle Look for a convenient existing ground such as a metal street sign Be careful not to get close to or cross any adjacent buried conductors If no existing ground is available use the ground spike...

Страница 16: ...increase as you approach the location of the conductor Peak VM 480B Receiver Response 5 2 3 Null Method To pinpoint the location of the conductor use the NULL method by holding the VM 480B receiver i...

Страница 17: ...nto the conductor when direct metallic contact is not possible The clamp is placed around the target conductor The transmitter then induces a signal through the clamp When using the Metroclamp the con...

Страница 18: ...ate by following steps 4 through 11 Section 5 2 Direct Connection 5 5 VM 480B 50 60Hz Power Line Locating When locating a power line the VM 480B transmitter is not required as you are locating the pow...

Страница 19: ...this procedure to estimate the depth of a buried conductor 1 Using the NULL method find the exact location of the conductor At a minimum distance of 35 feet from the transmitter to prevent air coupli...

Страница 20: ...Carrying Handle by placing the single screw end of the handle into the transmitter and securing it to the transmitter with the handle screw See below graphic Step 1 3 Place the mounted transmitter on...

Страница 21: ...heard and the visual indicator reads within the SET area Leave the topmost knob at that position If you are unable to find a no signal area lower the sensitivity Adjusting for Audio Balance 5 7 2 Loc...

Страница 22: ...xample in conduits ducts or pedestals use the method described below to identify a specific conductor 1 Apply transmitter signal to the target conductor using a 4820 Metroclamp as described in Section...

Страница 23: ...lease call your local One Call Center Conductor Electric power lines cables or conduits Communication lines cables conduits CATV Gas oil petroleum or other gaseous materials Storm and sanitary sewers...

Страница 24: ...acing Verifying means to confirm that a conductor if present and tracing means to map out its route along the ground Besides its use for locating a cable the VM 480B s 50 60Hz power line locating mode...

Страница 25: ...cing job will be easier if an assistant follows behind with the transmitter as you trace with the receiver 6 7 Locating a Service Lateral Active Range Inductive Mode After you have traced the main you...

Страница 26: ...ptly you are probably no longer over your targeted conductor 6 11 Congested Areas If you suspect that coupling from adjacent conductors is causing interference in the signal picked up by the receiver...

Страница 27: ...ollow established safety procedures 6 15 Distribution Systems To locate short gas services on a gas distribution system you should temporarily ground the end of the service This can be accomplished by...

Страница 28: ...he batteries lose power If it does not blink at all the batteries need to be replaced 3 To test the receiver batteries turn the Range Knob to NORM The needle on the field strength indicator should mov...

Страница 29: ...rmation visually available on the dot matrix display A generic term for any buried pipe or cable A minimum response to a buried line A locate where the receiver searches for a wide range of signals th...

Страница 30: ...or in Frequently used for locating sewer cameras and the non metallic pipes The buried pipe or cable to be located Using a locator to following the path of a buried line Response Search sweep Sonde Ta...

Страница 31: ...Notes info wctproducts com 13309 Beach Ave Marina del Rey CA 90292 wctproducts com Phone 800 WCT PROD 928 7763 Fax 310 306 9343...

Страница 32: ...info wctproducts com 13309 Beach Ave Marina del Rey CA 90292 wctproducts com Phone 800 WCT PROD 928 7763 Fax 310 306 9343...

Отзывы: