A/A DC INVERTER U-MATCH AIR CONDITIONERS PRODUCT
5
3 FUNCTION
Function
Description
Memory function
when unit restarts after power off, it will run on former status, the mode and
parameter are kept the same
Remote control function
wireless controller and remote controller can be selected, and the maximum
control distance of remote controller is 10m.
Timing function
it can timing ON/ OFF separately, meanwhile, it can also timing on circularly
Self-diagnosis with
alarm function
Once the unit has malfunction, the malfunction code will be indicated and alarm
rings immediately
Sleep function
it can self control for saving energy in energy saving mode.
Automatic function
the fan of indoor unit can adjust fan speed automatically based on actual
demand when cooling or heating under automatic mode
Cool air proof function
the fan starts only when the temperature of indoor unit heat exchanger is higher
than indoor temperature under heating mode
Weekly Time
Centralized Control and Weekly Timer Functions: The centralized controller and
the weekly timer are integrated in the same wire controller. The system has both
the centralized control and the week timing functions. Up to 16 sets of units can
be controlled simultaneously by the centralized controller (weekly timer). The
weekly timer has the function of invalidating the lower unit. The weekly timing
function is able to realized four timing ON/OFF periods for any unit every day, so
as to achieve fully automatic operation. No timing control can be set for holidays.
High/low pressure
protection
when suction pressure is too low or discharge pressure is too high, compressor
will stop and unit display malfunction code
Overload protection
compressor has its own overheat protection.Once the temperature of
compressor is higher than allowable level, compressor will stop and only when
temperature recovery, compressor restart
Over current protection
once the current of compressor is higher than normal level, compressor will stop
and unit display malfunction code
Discharge high
temperature protection
once the discharge temperature of compressor is higher than allowable value,
compressor will stop and unit display malfunction code
Reverse (open) phase
protection
once the phase sequence of power supply is incongruent or the phase is absent,
unit can’t work.
Anti-high temperature
protection
once the heat exchanger temperature of indoor unit is too high, the outdoor fan
motor will stop.
Timing ON/OFF display
display and timing turn ON/OFF time
(
only with wired controller have this
function
)
Fan speed display
display the speed (high,medium,low) of fan
(
only with wired controller have this
function
)
Function model display
cooling mode,dry mode,heating mode,fan mode
(
only with wired controller have
this function
)
Testing display
display testing mode
(
only with wired controller have this function
)
Temperature display
display room temperature and set temperature
(
only with wired controller and
remoter board have this function
)
Содержание ACP-12CC35GECI
Страница 2: ......
Страница 3: ...GREE COMMERCIAL AIR CONDITION A A DC INVERTER U MATCH AIR CONDITIONERS 1 PRODUCT ...
Страница 15: ...GREE COMMERCIAL AIR CONDITION A A DC INVERTER U MATCH AIR CONDITIONERS 22 CONTROL ...
Страница 16: ...A A DC INVERTER U MATCH AIR CONDITIONERS CONTROL 23 CONTROL 1 OPERATION FLOWCHART 1 1Cooling Dry Operation ...
Страница 17: ...A A DC INVERTER U MATCH AIR CONDITIONERS CONTROL 24 1 2 Heating Operation ...
Страница 52: ...GREE COMMERCIAL AIR CONDITION A A DC INVERTER U MATCH AIR CONDITIONERS 59 5 3 7 Dimensions ...
Страница 53: ...GREE COMMERCIAL AIR CONDITION A A DC INVERTER U MATCH AIR CONDITIONERS 60 INSTALLATION ...
Страница 76: ...GREE COMMERCIAL AIR CONDITION A A DC INVERTER U MATCH AIR CONDITIONERS 99 MAINTENANCE ...
Страница 95: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 118 IPM module protection ...
Страница 96: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 119 DC busbar overvoltage protection ...
Страница 97: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 120 DC busbar undervoltage protection ...
Страница 98: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 121 Abnormal noise from PFC inductor ...
Страница 99: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 122 Radiator overheat protection ...
Страница 100: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 123 Tripping ...
Страница 172: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 224 Model ACP 24CC70GECI ACP 24CF70GECI Exploded View ...
Страница 176: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 242 Model ACP 12CC35GECI Exploded View ...
Страница 178: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 244 Model ACP 18CC50GECI Exploded View ...
Страница 182: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 249 Model ACP 36CC100GECI Exploded View ...
Страница 188: ......
Страница 189: ......
Страница 190: ......