GREE COMMERCIAL AIR CONDITION A/A DC INVERTER U-MATCH AIR CONDITIONERS
56
5.3.3 Functions of Press Buttons
Table 2: Functions of Press Buttons
No. Name
Function
Description
1
Mode
It is used for the switchover among different modes
2
Fan
It is used to set the fan speed,
high
,
medium
,
low
or
auto
.
3
On/Off
It is used to set the on/off status of the indoor unit.
4
▲
5
▼
1. Under the single/centralized control status
:
It is used to set the running temperature
of the indoor unit with max.30
℃
anmin.16
℃
.
2. Under the timing setting status
:
It is used to set the timing period with max.24 hours
and min.0 hour.
3. Under the clock setting status: it is used to set the hour (max.:23, min.: 0) and minute
(max.:59, min.: 0) of the clock.
6
Mon
1/9
It is used for the switchover between unit 1 and unit 9;
Under the timing or clock setting status, it indicates Monday.
7
Tue
2/10
It is used for the switchover between unit 2 and unit 10;
Under the timing or clock setting status, it indicates Tuesday.
8
Wed
3/11
It is used for the switchover between unit 3 and unit 11
Under the timing or clock setting status, it indicates Wednesday.
9
Thu
4/12
It is used for the switchover between unit 4and unit 12
Under the timing or clock setting status, it indicates Thursday.
10
Fri
5/13
It is used for the switchover between unit 5and unit 13
Under the timing or clock setting status, it indicates Friday.
11
Sat
6/14
It is used for the switchover between unit 6 and unit 14;
Under the timing or clock setting status, it indicates Saturday.
12
Sun
7/15
It is used for the switchover between unit 7 and unit 15
Under the timing or clock setting status, it indicates Sunday.
13
8/16
It is used for the switchover between unit 8 and unit 16
14 Timer/Time
It is used to set the timing or on/off time of the selected indoor unit as well as to set the
clock of the system.
15
Central
It is used for the switchover between single and centralized control modes.
16
Shield
It is used to deactivate some or all functions of a single or a group the indoor unit(s).
17
All on/off
It is used to start/stop all indoor units.
5.3.4 LCD of the Controller
Outline Drawing of the LCD
Fig.1 Outline Drawing of the LCD
Содержание ACP-12CC35GECI
Страница 2: ......
Страница 3: ...GREE COMMERCIAL AIR CONDITION A A DC INVERTER U MATCH AIR CONDITIONERS 1 PRODUCT ...
Страница 15: ...GREE COMMERCIAL AIR CONDITION A A DC INVERTER U MATCH AIR CONDITIONERS 22 CONTROL ...
Страница 16: ...A A DC INVERTER U MATCH AIR CONDITIONERS CONTROL 23 CONTROL 1 OPERATION FLOWCHART 1 1Cooling Dry Operation ...
Страница 17: ...A A DC INVERTER U MATCH AIR CONDITIONERS CONTROL 24 1 2 Heating Operation ...
Страница 52: ...GREE COMMERCIAL AIR CONDITION A A DC INVERTER U MATCH AIR CONDITIONERS 59 5 3 7 Dimensions ...
Страница 53: ...GREE COMMERCIAL AIR CONDITION A A DC INVERTER U MATCH AIR CONDITIONERS 60 INSTALLATION ...
Страница 76: ...GREE COMMERCIAL AIR CONDITION A A DC INVERTER U MATCH AIR CONDITIONERS 99 MAINTENANCE ...
Страница 95: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 118 IPM module protection ...
Страница 96: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 119 DC busbar overvoltage protection ...
Страница 97: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 120 DC busbar undervoltage protection ...
Страница 98: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 121 Abnormal noise from PFC inductor ...
Страница 99: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 122 Radiator overheat protection ...
Страница 100: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 123 Tripping ...
Страница 172: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 224 Model ACP 24CC70GECI ACP 24CF70GECI Exploded View ...
Страница 176: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 242 Model ACP 12CC35GECI Exploded View ...
Страница 178: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 244 Model ACP 18CC50GECI Exploded View ...
Страница 182: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 249 Model ACP 36CC100GECI Exploded View ...
Страница 188: ......
Страница 189: ......
Страница 190: ......