INSTALLATION OF BATHTUBS

Installation of Bathtubs with panels

1

5

6

7

8

2

3

4

9

10

11

12

Points that Require Attention:

•  We recommend the bathtub to be installed after tiling the wall tiles and other construction related works in the bathroom are completed.
•  The technical details of the bathtub is provided in the Technical Data Sheet.
•  Faucets should be installed as shown on the Technical Data Sheet.
•  If a wall-mounted bathtub mixer is preferred the appropriate mixer should be installed on the wall in accordance with the instructions 

provided in the Technical Data Sheet. 

•  It should be ensured that the floor tiles are even and the walls are straight (90 °) before starting installation.
•  Cold and hot water connections must already be realized.
•  If this is a hydromassage bathtub the electrical connection should be prepared as shown in the Technical Data Sheet. 

1-  The bathtub should be installed to a structurally prepared floor.
2-  If the bathtub is purchased with a packaging on pallets, the leg sets must be installed to the bathtub. In this case the leg profiles are prepared to 

be installed on the bathtub. The bathtub is placed upside down on a clean floor and the U shaped legs are inserted to the toggle and fixed to the 
bottom of the product via two screws. 

3-  The toggle screws are tightened.
4-  Remove the protective folio of the bathtub from its sides that are touching the wall and from the area around the siphon.
(Note: The remaining protective folio on the bathtub should be removed only after the bathtub installation and other construction works in the 
bathroom are finished.)

5-  Place the bathtub to the installation area.
6-  Adjust and level the leg set according to the height of the panel. Check the evenness with a scale. (See the Technical Data Sheet for the panel 

height).

7-  Tighten the let sets nuts.
8-  Mark the leg set installation holes (Caution! No hole should be drilled on heated and isolated floors!)

9-  The points on the wall tiles which are marked for installing the wall hangers are drilled with a drilling machine (tip 10) and the wall hangers are 

fixed (The technical details are given in the "Wall Hanger Details” section of the Technical Data Sheet.)

10-  Prepare the bathtub siphon for installation. (At this stage do not forget to remove protective folio on the bathtub around the siphon hole.)
11-  Apply silicone on the siphon drain seal and the bearing seal,
12-  Install the bathtub siphon you’ve prepared.

Содержание Neon

Страница 1: ...ft Aqua Maxi Air Relax Aqua Soft Aqua Soft Easy 3 Front View Ön Görünüş 2 Side View Yan Görünüş As shown in Figure Plan the wall hangers details A B are used to fix the product to the wall It is suggested to use the wall hangers to rigid the shower tray Plan görüntüde şekil 1 A ve B olarak gösterilen duvar askı elemanları ürünü duvara sabitlemek amacıyla kullanılır Duş teknesinin rijitliğini sağla...

Страница 2: ...n için ek pay b rak lmas na gerek yoktur Ürünün ebad dikkate al narak gereken alan n haz rlanmas yeterlidir The area where the waste outlet Ø 50 mm can be placed in A Ideal position of the waste outlet Ø 50 mm The end point of the waste outlet should not be cut out and should be left at least 50 mm above the surface B The area Ø 200 mm where the waste outlet should not be left C Hot cold water inl...

Страница 3: ... Artema Yetkili Servisleri ne Ücretsiz olarak yaptırılması gerekmektedir Masajlı Küvetler in Ücretsiz Montaj Uygulaması kapsamına standart bir küvet montajında kullanılan VitrA silikon dirsek ve 50 mm lik uzatma hortumu da dahildir Kenar çıtası gibi ilave aksesuarlar bu uygulamaya dahil değildir Masajlı Küvetler in gömme uygulamasında kesinlikle havalandırma ve müdahale kapakçığı bırakılmalıdır Bu...

Страница 4: ...duct should be protected with an appropiate ampere fuse for Aqua Nano System 16 ampere Duo Maxi and Duo Soft Systems 16 ampere for Aqua Maxi Aqua Soft Aqua Soft Easy and Air Relax System 10 ampere and the amper fuse should be closed when it is not used Küvet masajlı ise uygun Amperdeki sigorta ile koruma altına alınmalıdır Sigorta akım değeri Aqua Nano sistemi için 16 Amper Duo Soft ve Aqua Maxi s...

Страница 5: ...ACRYLIC BATHTUBS Installation Applications and User s Manual ...

Страница 6: ...s Not Covered Under Warranty 11 Transportation Storage 11 Installation 11 Use Cleaning and Maintenance 11 November 2015 www vitra com tr Manufacturer Company Eczacıbaşı Yapı Gereçleri San ve Tic A Ş Șekerpınarı Cumhuriyet Mah İsmet İnönü Cad No 27 41420 Çayırova Kocaeli Tel 0262 648 95 00 Pbx Faks 0262 658 85 94 Consultancy Line 0850 311 70 70 0532 755 75 00 General Distribution Central Service İn...

Страница 7: ...rom our seller for the telephone number of the Authorized Service in the area you are living in In places where we do not have a seller you may get the necessary information from the telephone numbers given in the guide Ask the service personnel to display their Vitra Artema Authorized Service Personnel Card Do not let people without a personnel card perform the installation At the completion of t...

Страница 8: ...not deform Any small scratches which might occur on the surface can easily be eliminated through polishing Acrylic products do not lose their shine due to a homogenous distribution of color cells and saves the first day appearance over years The acrylic plates used in the production of VitrA Acrylic Bathtubs meet the EN 263 Standards for Acrylic Plates and are supplied from Lucite International ICI...

Страница 9: ... The bathtub is placed upside down on a clean floor and the U shaped legs are inserted to the toggle and fixed to the bottom of the product via two screws 3 The toggle screws are tightened 4 Remove the protective folio of the bathtub from its sides that are touching the wall and from the area around the siphon Note The remaining protective folio on the bathtub should be removed only after the bathtu...

Страница 10: ...massage bathtub the electrical connection should be made 21 For rectangular bathtubs first the side panel and later the front panel are installed to the bathtub For corner bathtub panels fixed metal clips are available for panel installation under the front side rims of bathtub to fix the panel The panel s installation is started from one corner by attaching the top band of the panel to these clips 2...

Страница 11: ...adjusted in accordance with the technical drawing of the faucet See the Technical Data Sheet for the technical scheme 7 The parts of the bathtub s monobloc sides that touch the floor should be marked The panel supporting brackets should be pulled inside at the thickness of the acrylic and they should be fixed to the floor with silicone Accordingly movement of the bathtub on the floor is prevented 8 Th...

Страница 12: ...cal Features MASSAGE SYSTEMS IMPLEMENTED IN VİTRA BATHTUBS 8 If your VitrA bathtub without massage functionality is a model which is suitable for the implementation of a hydro massage system you can convert it into a massage bathtub and enjoy the pleasure of hydro massages You can have a suitable massage system installed to your VitrA plain bathtub you have purchased and are using anytime you want...

Страница 13: ...Automatic air massage intensity setting Intermittent air massage Continuous air massage Manual water massage intensity setting Automatic water massage intensity setting Intermittent water massage Continuous water massage pneumatic ABS or chrome coating 18 0 8 220 230 10 2 halogen lamps optional 12 0 04 220 230 10 chrome coating over brass chrome coating over brass 21 0 8 220 230 10 electronic elec...

Страница 14: ...earest VitrA Artema Authorized Service MATTERS THAT REQUIRE ATTENTION Acrylic is durable against acids and alkalines However do not let organic solutions used in dry cleaning paint remover substances acetone or other solvents to your compact system Keep lighted cigarettes away from the product If the construction activities in the bath will continue after installation do not remove the folio layer...

Страница 15: ... Products damaged by each other due to stacking on top of each other during storage shall be treated out of scope of the warranty Installation 1 Failures which occur as the result of incorrect installation maintenance repairs and disassembly performed by unauthorized persons 2 Factors which impact the installation of the product resulting from the wall or floor not being level or hot cold water was...

Страница 16: ......

Отзывы: