34
EN
Using the dirty filter will restrict
the airflow in the carburetor
affecting pump performance;
5.2 - SPARK PLUG (FIG.M)
To ensure proper engine operation,
the spark plug must be clean and
with adequate clearance between the
electrodes.
1. Remove the pipe (14), unscrew the
spark plug (14) and check that it is
clean;
2. Measure the distance between the
electrodes with a suitable tool. The
distance should be between 0.7-0.8
mm. If necessary bend the electrode
until adequate clearance is achieved;
3. Put the spark plug by hand to prevent
damage to the thread and tighten to
tighten the washer using the supplied
wrench;
4. If spark plug does not start spark,
replace;
The spark plug may overheat
and cause engine damage.
5.3 - GENERAL CLEANING
(FIG.N)
Clean the machine after each use.
Careful handling protects the machine
and extends its service life.
Before cleaning, let the engine cool
down completely, remove the hoses
from the water pump and wipe the
accessible surfaces with a damp cloth.
Cleaning the pump chamber
(FIG. N):
1. Remove the filler cap (12) and the
pump chamber drain;
2. Pour clean water into the filler hole
(12) until the pump chamber (8) is
completely clean;
3. Attach the pump chamber cap and
drain;
6. PROTECTION OF THE
ENVIRONMENT
The packaging is made up of
recyclable materials, which
you can dispose on local recycling
points.
Never place combustion
engines in the household
waste!
Waste such as old oil, fuel, lubricant,
filters and wear parts can harm human
beings, animals and the environment
and as such must be disposed of or
recycled.
Make sure that an already deactivated
machine is routed to be eliminated in a
technically correct manner.
You can obtain information regarding
the disposal of the used machine
through the legal responsible for the
recycling in your municipality.
7. CUSTOMER SERVICE
Phone: 256 331 080
E-mail: [email protected]
Website: www.centrallobao.pt
Содержание VIMB12TA
Страница 49: ......
Страница 50: ...RUA DA GÂNDARA 664 4520 606 S JOÃO DE VER STA MARIA DA FEIRA PORTUGAL MI_VIMB12TA_REV00_JAN18 ...