5
If using PoE, the heater will not operate at all.
If PoE and DC 12V are both applied, this camera will get supplied with power from PoE.
• Connecting Service Monitor Port (using VK2-LCT)
Service monitor output port (J7) is located on the board of the dome camera, and is used for an
easy OSD setup.
▶
ID & IP assignment
To make changes in the OSD menu, please use the OSD controller provided optionally with your
camera purchase. You can set Camera Title and IP Address.
1. Connect the OSD Controller to the Service Monitor port of the network camera.
2. Connect Service Monitor and the Video Output port of the OSD Controller.
3. Press the SET button to access main Menu.
4. Change Camera ID, and IP Address. You can change the Name or Title and IP address of the
camera. Using the
↑↓←→ buttons on the controller, you can change the parameters.
5. Select SAVE or CANCEL to exit the Main Menu.
Video Output is used for an easy zoom and focus control when installing lens. Video Output is
restricted to 704x480(576) resolution.
▶
Zoom & Focus Control
The camera enters Zoom and Focus control mode as soon as connecting OSD Controller to the
Service Monitor port.
-. Zoom Control:
↑(Zoom In), ↓(Zoom Out)
-. Focus Control:
←(Focus Near), →(Focus Far)
-. Smart Focus: Press and hold the SET button for 2 or more seconds. The camera readjusts
focus automatically.
Note:
You can get the Optional OSD Controller from your installer.