0150-0319A 12
Vista
Triplex
2
CDR/DVD
RS485 Connector
Wire Type:
#24 AWG, twisted pair with shield
(2-wire)
Connector Type:
RJ-45
Max. Cable Length:
3200 feet / 1000 meters
Shields are grounded at one end, preferably at the
Vista Triplex
2
CDR/DVD end.
See section 3.18 for information about configuring
the RS485 network address settings in the menu
system.
RJ-45 Pin Configuration For RS485 Port
Pin
Use
Pin
Use
1
Ground (Shield)
5
Not Connected
2 12Vdc
+ve
6 Network
-ve
3
Nve
7
Ground (Shield)
4 Not
Connected
8
12Vdc
+ve
8
2 3 4 5 6 7
1
RJ-45 socket on
back panel.
The 12Vdc power is used when connecting to the Vista NPX/RKB, if connecting multiple
Triplexes together the 12Vdc +ve must not be connected.
Ethernet Port
Wire Type:
Cat 5
Connector Type:
RJ-45
Max. Cable Length:
100 meters / 328 ft.
Min. Cable Length:
6 feet / 1.8 meters
Hub Wiring Configuration:
Straight Through
PC Wiring Configuration:
Cross Over
The cable connection configuration depends on your
network configuration:
•
For a Vista Triplex
2
CDR/DVD that connects
directly to a Hub or Switch, use a straight through
connection.
•
For a Vista Triplex
2
CDR/DVD that connects
directly to a PC, use a cross over connection.
Consult with your MIS personnel for the specific type
of configuration. See section 3.18 for information
about configuring the Ethernet settings in the menu
system.
RJ-45 Pin Configuration For Ethernet Port
Pin
Use
Pin
Use
1 TX+
5
Not
Connected
2 TX-
6 RX-
3 RX+
7
Not
Connected
4 Not
Connected
8 Not
Connected
8
2 3 4 5 6 7
1
RJ-45 socket on back
panel.
NOTE