![Visonic Fully supervised wireless accessories Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/visonic/fully-supervised-wireless-accessories/fully-supervised-wireless-accessories_accessories-manual_1032802020.webp)
RP-600 PG2
D-302758
19
REPEATERS (RP-600 PG2)
Wireless Repeater for PowerG Communications
1. INTRODUCTION
The RP-600 PG2 is a range
extender designed to relay digital
data between wireless
PowerMax10-G2 Devices and a
PowerMax10-G2 Control Panel.
Repeater links are required when
the Control Panel is beyond the
range of at least some of the
devices and is therefore incapable
of receiving transmissions directly
(see Figure 2).
Figure 1:
External View
2. SPECIFICATIONS
Frequency Band (MHz):
Europe 433, 868, USA: 915
Modulation Type:
FSK (Frequency Shift Key).
Antenna:
Built-in antenna
Communication Protocol:
PowerG II
AC Power Supply :
AC to AC adaptor.
120 VAC, 60 Hz / 9 VAC, 0.35 A min. (in the U.S.A.)
230 VAC, 50 Hz / 9 VAC, 0.35 A min.
Backup Battery:
4.8-Volt 1300 mAh NiMH rechargeable.
Note:
Dispose of used batteries according to the
manufacturer's instructions.
Current drain at 5.7 VDC
Frequency (MHz)
¨
433
868
915
100 mA 100
mA 100
mA
Battery Backup Duration
(with fully charged 1300 mA/h
battery) 48 hours:
LED indicator:
Green LED lights when AC power on.
Compliance with Standards
:
Europe:
EN 50131-1, EN 50130-5, EN 50131-6, EN
301489, EN 50130-4, EN 300 220
USA:
(FCC) CFR47 Part 15
Canada:
RSS210
Operating Temperature:
0°C to 49°C (32°F to 120°F).
Dimensions (H x W x D):
161x161x50mm (6-7/16 x 6-
7/16 x 1-3/4 in)
Weight: (with battery):
470g (16.5 oz.)
3. INSTALLATION
3.1 Repeater's Location Selection
A.
In a repeater setup, install the repeater where good
communication is assured with the target receiver and with
the transmitters deployed in the repeater's coverage area.
B.
Mount the repeater as high as possible above the floor
and well away from metal chimneys, large metal
cabinets, metal doors and reinforced concrete walls, all
of which may reduce the communication range.
C.
Make sure that the location you have selected is near
an electrical outlet.
1
2
3
(*)
4
For back
tamper screw
6
5
AC to AC
adaptor
Figure 2 - Installation
.