background image

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXAMPLE 2: 

To test the LNB input of a satellite receiver 

1.

 

Disconnect the satellite receiver from the wall socket or LNB 
feed cable. Connect the TV/SAT Power Tester DC IN (Source) to 
the satellite receiver input 1 or input 2. 

2.

 

Check the voltage is either 18V for horizontal or 13V for vertical 
polarity. If using a Sky Q receiver check there is 12V from either 
input. 

3.

 

If the voltage is correct, connect the TV/SAT Power Tester DC 
OUT (Load) to the wall socket or LNB. Press the red test button. 
Check the voltage and current display. 

4.

 

If the voltage displayed is now lower than at {step3.} or the 
current is higher than the equipment ratings label, there is a 
fault in the installation. Check the 22 KHz LED is illuminated if a 
high-band signal is selected. 

5.

 

Any fault is most likely found at a connection point, such as a 
whisker of coaxial cable braid shorting across the centre 
conductor in the wall socket or at a connector. The fault could 
also be a faulty LNB or line amplifier. 

Note: Sky HD receivers have 2 inputs.  Each can independently supply 

13V or 18V DC up to a combined maximum of 275mA. 

 

Note: SkyQ receivers have 2 inputs. Each input can supply only 12V DC 

up to a combined maximum up to 275mA. 

 

Содержание V18-310

Страница 1: ...V18 310 TV SATELLITE DC Power Tester...

Страница 2: ...est the 12V supply to a masthead amplifier Page 5 Test the LNB input of a satellite receiver Page 7 Test the LNB input of IRS Page 9 Test the PSU and load on IRS installation Page 11 Test the voltage...

Страница 3: ...llite systems connected to legacy satellite receivers SKY Sky HD Sky Q Freesat Freesat HD dSCR SCR and DiSEq installations etc IMPORTANT The V18 310 TV SAT Power Tester requires a PP3 6LR61 MN1604 9V...

Страница 4: ...Do not use the product if you suspect it has been damaged in any way including being dropped is malfunctioning or has been exposed to liquids or moisture The unit must be repaired by an authorised ser...

Страница 5: ...t move or carry the product by any other means other than the case as a whole or handle if provided This product complies with the relevant clauses of the European Directive 2002 96 EC The unit must b...

Страница 6: ...ead amplifier to the TV SAT Power Tester Load 5 Press the red test button Check the voltage and current display 6 If the voltage displayed is now lower than at step 4 or the current is higher than the...

Страница 7: ...6...

Страница 8: ...7...

Страница 9: ...the voltage and current display 4 If the voltage displayed is now lower than at step3 or the current is higher than the equipment ratings label there is a fault in the installation Check the 22 KHz LE...

Страница 10: ...9...

Страница 11: ...t the TV SAT Power Tester DC OUT Load to the LNB feed marked H Lo green cable 4 Press the red test button Check the voltage and current display 5 If the voltage displayed is now lower than at point c...

Страница 12: ...ss and hold the red test button 6 Check the voltage remains at 18V when under load 7 Add the current rating for each device on the system including all multiswitches the LNB and any amplifier 8 Check...

Страница 13: ...12...

Страница 14: ...13...

Страница 15: ...TV SAT Power Meter to the H Lo terminal of the next piece of equipment in the trunk network to power the system 6 Press and hold the red test button 7 Read the current consumption of the system Does t...

Страница 16: ...2017 Vision Products Europe Ltd Redbourne Park Brackmills Northampton NN4 7DT www vision products co uk technical vision products co uk 01604 664758...