![Vision Tech Shop TVC Series Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/vision-tech-shop/tvc-series/tvc-series_tehnical-manual_1032157025.webp)
TVC Counting Scale Technical Manual (v1.09b-v1.11)
- 25 -
Err 15
Gravity error
Check the gravity settings.
Gravity range must be 0.9xx ~
1.0xx
Err 16
Paper error
Check the printer paper
Err 17
Tare out of range
Minus weight or overload.
Remove the load and restart
scale again.
Err 18
Pre-tare error
Check the pre-tare value
Err19
Initialize
zero error
Calibration the scale.
Err P
Printer error
Check the printer settings or
connections
Err l
Approval setting error
Check the PCB jumper
settings. Must be connect
jumper pin to K1 (BW series)
--ol--
Over range
Remove the load.
Re calibrate
--lo--
Underload
Minus weight, check the
platform and restart or
calibrate.
Fai l h
/
fai l l
/
fai
l
Calibration Error
Check the test weights & Re
calibrate
Ba lo
/
lo ba
Battery low
Re charge battery, check the
voltages.