TVC Counting Scale Technical Manual (v1.09b-v1.11)
- 18 -
7. CALIBRATION
7.1 Linear Calibration
1.
Turn on the scale.
2.
Press and hold
key during the self-test.
Display will show
“
Pn
”
briefly PIN is activated. Press the PIN number to get into
the parameter menu.The default PIN number is “9999”
3.
Press numeric key 9 four times, display will be shown
Pn - - - -
4.
Press
key to confirm, It will enter into the parameter settings and show
“
menu unit lb
” .
a.
If calibrating in
lb
, continue step 6
b.
If calibrating in
kg
, press
key,
kg
will be show on the display
5.
Make sure there are no loads on the platform
PS: Press
key to choose "kg" or "lb" unit, capacity will be show
in kg or lb values.
Press calibration switch to enable settings; the calibration switch is located
below the scale.
6.
Press
key to confirm, display will be show “
F0 CAL
”
7.
Press
key to select “
F1 lCAL
”.
8.
Press
key to confirm, display will be show “
unLoAd”
After stable indicator on and in zero point
9.
Press
key to confirm, display will be show “
cal load 1”
Place the first weight on the platform,
10.
Press
key to confirm, display will be show “
cal load 2”
Place the second weight on the platform,
11.
Press
key to confirm, display will be show “
cal load 3”
Place the third weight on the platform,