Heart-Rate-Control Console Engineering Mode Guide
Enter Engineering Mode.
1. Turn power on, then holding
SLOW
and
UP
key simultaneously about 5 seconds.
2. The center window shows
"Eng1"
. Press
ENTER/SELECT
key to set From “P0 to P8”.
3.
P6: unit
00: T-8500 (ml) 01: T-8500 (kl)
02: T-8600 (ml) 03: T-8600 (kl)
04: T-8400 (ml) 05: T-8400 (kl)
06: T-8200 (ml) 07: T-8200(kl)
u
Press ENTER/SELECT key to store.
P0: min. speed
0.5ml (1.0kl)
u
Press ENTER/SELECT key to store.
P1: max. speed
For T-8500/T-8400/T-8200 is 10.0ml (15.0kl)
For T-8600 is 12.0ml (18.0kl)
u
Press ENTER/SELECT key to store.
P2: mid. speed
For T-8500 / T-8400 / T-8200 is 5.0ml (7.5kl)
For T-8600 is 6.0ml (9.0kl)
u
Press ENTER/SELECT key to store.
P4: min. elevation
u
Press ENTER/SELECT key to store.
P5: max. elevation
u
Press ENTER/SELECT key to store.
P7: max. time...................99
u
Press ENTER/SELECT key to store.
P8: user weight................80(kg) or 150(lb)
u
Press ENTER/SELECT key to store.
Press UP or DOWN key to reach P0~P8 address.
Press SLOW or FAST key to
choose unit
Press SLOW or FAST key to
calibrate the speed
Press SLOW or FAST key to
calibrate the speed
Press SLOW or FAST key to
calibrate the speed
Press SLOW or FAST key to
calibrate the elevation
Press SLOW or FAST key to
calibrate the elevation
Press SLOW or FAST key to
choose the running time
Press SLOW or FAST key to
input the user's wight
4-1 Revision: 1.0 Date: 2001-06-01
Содержание Vision Series
Страница 1: ......
Страница 4: ...SECTION 1 MAINTENANCE PROCEDURE ...
Страница 10: ...SECTION 2 IMPORTANT SAFETY INSTRUCTIONS ...
Страница 12: ...SECTION 3 WIRING DIAGRAM INSTRUCTION ...
Страница 19: ...SECTION 4 CONSOLE ENGINEERING MODE GUIDE ...
Страница 23: ...SECTION 5 MCB LED INSTRUCTIONS ...
Страница 30: ...SECTION 6 TROUBLESHOOTINGS ...
Страница 42: ...SECTION 7 PARTS REPLACEMENT PROCEDURE ...
Страница 67: ...SECTION 8 SERVICE FORM ...