manualshive.com logo in svg
background image

ENGINEERING

GUIDES

1

Date of last revision: 2.06

TREADMILL.UPPERBDENG.DELUXE.REV1

S T A N D A R D   C O N S O L E   F O R :

(T9200 DELUXE, T9500 DELUXE, T9600 DELUXE, T9250 DELUXE, T9450 DELUXE)

DELUXE (6-WINDOW) UPPER BOARD

ENGINEERING GUIDE

Содержание T9200 DELUXE

Страница 1: ...IDES 1 Date of last revision 2 06 TREADMILL UPPERBDENG DELUXE REV1 S T A N D A R D C O N S O L E F O R T9200 DELUXE T9500 DELUXE T9600 DELUXE T9250 DELUXE T9450 DELUXE DELUXE 6 WINDOW UPPER BOARD ENGI...

Страница 2: ...In Mode Runs continuous program Eng 4 Auto Calibration Mode Calibrates both speed and elevation Eng 5 Speed Sensor Test Tests speed sensor functionality Eng 6 Exit Exit engineering mode ENG1 EDIT VAR...

Страница 3: ...0 80 400 P9 Accumulated Time N A N A N A P10 Accumulated Distance N A N A N A P11 Belt Thickness depending on model 16 44 P12 Roller Diameter 60 60 60 P13 Elevation motor 1 N A N A P14 Pause Time 5 00...

Страница 4: ...start is at half max The user can adjust the speed and incline The program returns to the preset incline upon segment completion Keyboard functions are the same as in normal operating mode ENG 4 AUTO...

Страница 5: ...er is still being applied to the board This safety switch condition occurs in any mode including engineering modes When the magnet reconnects to the console the board resets Any activity or run time i...

Страница 6: ...red user programs Changing units may also require you to perform auto calibration MAX TIME P7 represents the maximum time which is displayed in the upper right window This is the maximum amount of tim...

Страница 7: ...ing To begin auto calibration press START The treadmill will run through minimum and maximum speed and maximum incline this will take three to five minutes Let the treadmill perform this complete func...