B: Outside Magnetic Brake Control System: Adjust the resistance to the max. The distance
between the magnets and the pulley shall be 1.8-2mm. If the distance is not in this range,
adjust it to the proper position by moving the two screws at the frame. (Fig. K)
(Fig. K)
3. If the console wire & the console & the ECB motor all work well, the magnetic brake control
equipment is defective. Replace it.
6.3 No Power to the Console
Symptom:
The adaptor and power switch is in the on position, but the console will not turn on.
Reason:
1. The Adaptor is defective.
2. The console wire is defective.
3. The console is defective.
Solution:
Adjust the steel cable