![background image](http://html1.mh-extra.com/html/vision-fitness/e1500-frame-9/e1500-frame-9_service-manual_1031781017.webp)
17
5. Use a multi-meter to check if the console wire is conductive. If not, the console wire is
defective, and replace it.
6. Replace the console set if all above can not resolve the issue. .
6.2 Resistance Inaccurate
Reason
:
1. The console cable or the console or ECB motor is defective.
2. The steel cable location is not correct or ECB motor is not assembled properly.
3. The magnetic control equipment is defective.
Solution
:
1. Check if the ECB motor works. Enter Engineering Mode (See Chapter 3), and scroll to ENG
2 (Machine Test).Press the key “ENTER” first, and then press the resistance UP
▲
or
DOWN
▼
keys . The left window display the rounds of ECB motor moving.
- If the figure is up or down, the ECB motor works well.
- If it is always “0”, the ECB motor or the wiring is defective. Replace the ECB motor if it is
defective.
(Fig. H)
2. A. Inside Magnetic Brake Control system: Check the gap between the orange block and the
bottom. The distance shall be within 1-2 mm. If the gap is bigger than 1-2 mm, adjust the
steel cable to the correct gap range. (Fig. I)
、
(Fig. J)
(Fig. I)
Inside Magnetic Brake
Control system:
RPM
Содержание E1500 Frame 9
Страница 8: ...8 CHAPTER 4 ELECTRON DIAGRAMS 4 1 RB130 2KM C BECS_9 ...
Страница 9: ...9 4 2 CB142B 2KM F E3200 FRAME_9 ...
Страница 10: ...10 4 3 CB143 2KM F E1500 FRAME_9 ...
Страница 11: ...11 4 4 RB135 2KM F R2250 FRAME_9 ...
Страница 12: ...12 4 5 RB133 2KM F R1500 FRAME_9 ...
Страница 13: ...13 4 6 EP225 2KM F X6200 FRAME_9 ...
Страница 14: ...14 4 7 EP224 2KM F X1500 FRAME_9 ...