![background image](http://html1.mh-extra.com/html/vision-fitness/e1500-frame-9/e1500-frame-9_service-manual_1031781019.webp)
19
1. Check if the LED at the adaptor is lit. If it is not, try a different outlet. (Fig. L)
- If the LED is still not lit with a known good outlet, the adaptor is defective and replace it.
(Fig. L)
Check if the power switch works. Use a multi-meter to check the negative and positive of
power switch. If the multi meter displays output DC 12V, then the power switch is good. If it
is not, the power switch is defective and replace it. (Fig. M)
(Fig. M)
2.Remove the console cable from the PCB, and use a multi-meter to measure the output DC
voltage of the console cable( pin GND and PIN VCC). If it is not output DC 12V, the console
cable is defective and replace it. (Fig. N)
、
(Fig. O)