Getting Started VC Smart Cameras
36
8.3 Camera Shell access via Terminal Program (TeraTerm)
Follow these step by step instructions for establishing a connection with the camera shell via
TeraTerm. The left hand side shows the steps for communicating with an Ethernet camera – the right
hand side displays the connection with a serial camera.
Both interfaces – Telnet Port 23 via TCP/ IP and the serial interface work the same way once
established:
Shell commands or program IO functions (like print instructions or so called “RS232 (V24) functions” in
the VCRT5 manual) behave in an identical way.
See Appendix D for troubleshooting advice on Telnet and RS232 communication.
Ethernet Cameras
Serial Cameras
1. At TeraTerm start up select “TCP/IP” and
“Telnet” and specify the camera IP
address (shown at startup video output).
The default IP address is 192.168.0.65 as
shown.
2. Confirm your input selecting “OK”
1. Select “Serial” and the connected COM
port (ensure the voltage level of the serial
interface is sufficient or use USB to serial
converter, see section
Fehler!
Verweisquelle konnte nicht gefunden
werden.
)
2. Confirm
with
“OK”
3. The TeraTerm window asks for a
password (Telnet feature). Password input
is not required – confirm with “Return”.
3. At the main TeraTerm Window adjust the
serial port settings if required (under
“Setup” -> “Serial Port”. Select the default
settings as shown.
Default baud rate is 9600Bd as shown.
1996-2011 Vision Components GmbH Ettlingen, Germany