34
Viscount - Advanced Manual
Prestige
MIDI CHANNELS RECEIVE
Pedal:4
Great:2
Swell:1
Prestige 70 - 60 - 50 - 40:
NOTA
MIDI channel n.° 16 is not available because it is a System channel used by internal Viscount
MIDI code.
Now press [EXIT] to return to the MIDI menu and save the settings made.
Now the CURSOR [
] key can be pressed again to display the MIDI channel coupling video page.
MIDI CHANNELS COUPLING:disable
With this function enabled, if one manual is coupled to another the organ transmits the MIDI notes
simultaneously on the two channels of the sections which are playing, as if the organist were
actually playing on both manuals.
This feature is useful if you wish to play two different sections on a remote expander which is not
capable of understanding Viscount’s exclusive messages for the couplers activation and deactivation.
However, since the Prestige transmits these MIDI messages using Viscount expanders or remote
sequencers that will retransmit the data to the organ, it is best to deactivate this function because
the coupling notes will then be regenerated by the receiver instrument.
This prevents the generation of double notes (the note received plus the note generated by the
coupling) which might cause undesirable effects, especially a reduction of polyphony and the
triggering of problems relating to timbre.
As the display prompts, select
ENABLE
to activate channel coupling or
DISABLE
to deactivate
it.
Содержание Prestige Organs