Dosing system eco-CONTROL EC200 DUO
Operating and maintenance instructions
Version 1.4
Copyright ©
8.3.2
Logical links of the outputs
Dosing (system plug 15, pins O1C + O1E)
The output has H-level during the dosing
process, otherwise it has L-level.
Fill level alarm (system plug 19, pins OFC + OFE)
The output is activated following
successful initialisation (H-level). It switches to L-level if the connected fill level sensor
switches to L-level.
Under system and error messages, the fill level monitoring function on page 26 in chapter
5.10.14 can be used to activate or deactivate the monitoring of the sensors.
Ready (system plug 19, pins ORC + ORE)
An initialization is carried out after the
control system has been switched on. The output is activated when the initialization has
been successfully completed (H-level).
Error output (system plug 19, pins OEC + OEE)
The output is activated following
successful initialisation (H-level). If vacuum, overpressure or overcurrent is registered,
the output switches to L-level.
Connections for primary pressure monitoring
The sensors for primary pressure
monitoring are connected to the connections Input Pressure A and Input Pressure B (24).
Entering the tolerance value is described on page 22 in Section 5.10.10.
System plugs (19)
Pin
Type
Area
Item
I0A
galvanically separated
max. 24V/10mA
not set
I0C
galvanically separated
I1A
galvanically separated
max. 24V/10mA
not set
I1C
galvanically separated
OFC Collector*
max. 30V/10mA
Fill level alarm (no alarm=transistor
interconnected)
OFE Emitter*
ORC Collector*
Ready for operation (no error=transistor
interconnected)
ORE Emitter*
OEC Collector*
Error output
OEE Emitter*
* galvanically separated
Содержание PreeFlow eco-CONTROL EC200 DUO
Страница 2: ...Item number 20202 print 21 2 12 ...
Страница 39: ...Dosing system eco CONTROL EC200 DUO Operating and maintenance instructions Copyright Version 1 4 39 43 ...
Страница 40: ...Dosing system eco CONTROL EC200 DUO Operating and maintenance instructions 40 43 Version 1 4 Copyright ...
Страница 41: ...Dosing system eco CONTROL EC200 DUO Operating and maintenance instructions Copyright Version 1 4 41 43 ...
Страница 44: ......