VPOD OPERATOR'S  MANUAL

 

 

CONTENTS 

CHAPTER 1 INTRODUCTION ................................... 1

 

1.1 BRIEF INTRODUCTION ........................................................................................... 1

 

1.3 ELECTROMAGNETIC COMPATIBILITY.................................................................. 2

 

1.4 EQUIPMENT CLASSIFICATION .............................................................................. 2

 

2.1 OUTER VIEW ............................................................................................................ 2

 

2.2 INSTALL THE BATTERIES ...................................................................................... 3

 

2.4 MONITORING ........................................................................................................... 3

 

2.5 FACTORS THAT MAY AFFECT THE MEASUREMENT .......................................... 3

 

3.1 DISPLAY ................................................................................................................... 4

 

3.2 MODE INTRODUCTION ........................................................................................... 4

 

3.3 KEY FUNCTIONS ..................................................................................................... 4

 

3.4 DATA REPLAY AND TRANSMISSION..................................................................... 5

 

CHAPTER 4 MAINTAINANCE AND REPAIR............ 5

 

4.1 MAINTENANCE ........................................................................................................ 5

 

4.2 TROUBLESHOOTING .............................................................................................. 5

 

4.3 WARRANTY AND REPAIR ....................................................................................... 6

 

APPENDIX A    SPECIFICATIONS............................. 7

 

APPENDIX B .............................................................. 7

 

 

 

 

 
CHAPTER 1 INTRODUCTION   
 
1.1 Brief Introduction 

Thank you for purchasing the handheld pulse oximeter for SpO

2

 and Pulse Rate (PR) measurement. The pulse oximeter features PR tone modulation, data storage and data transmission capabilities. 

Please read the operator's manual carefully before using this instrument. 
 

Intended use

: The purpose and function of the handheld pulse oximeter is to indicate measure and display the functional oxygen saturation of arterial hemoglobin (SpO

2

) and pulse rate for adults and 

pediatric patients in hospital, ambulatory, home, and EMS (emergency medical service) environments. The pulse oximeter is intended for spot-checking these levels and not indicated for continuous 
monitoring. It can assist the clinician diagnostically by quickly displaying the patient’s %SpO

2

 and pulse rate and can additionally store 72 hours of data. 

 

Measurement principle

   

The principle of pulse oximetry is based on the red and infrared (IR) light absorption of oxygenated and deoxygenated hemoglobin present in the circulating blood. Oxygenated hemoglobin absorbs 
more IR and allows more red light to pass through. Deoxygenated hemoglobin conversely absorbs more red light and allows IR light to pass through. The detector probe is placed on the finger. The 
probe contains two light emitting diodes (LED’s), one in the visible red spectrum (660nm) and one in the IR spectrum (940 nm). The beams of light from this probe pass through the tissues and some 
light  is  absorbed  by  the  blood  and  soft  tissues  depending  on  hemoglobin  concentration.  The  amount  of  light  absorption  at  each  light  frequency  is  dependent  on  the  degree  of  oxygenation  of 
hemoglobin within the tissues. 

 

The microprocessor can select out the absorbance of the pulsatile fraction of blood, i.e. that due to arterial blood, from constant absorbance due to non-pulsatile venous or capillary blood and other 
tissue pigments   

 

 

 

Principal of Operation 
1.    Red and Infrared-ray Emitter Diode 
2.    Red and Infrared-ray Receptor Diode 

 
1.2 Safety Information

   

Warning, Precaution and Notice 

 
Warning, Precaution and Notice in the manual are special information that prompts the operator’s attention.   
 

Warning - Information concerning something that could possibly hurt the patient or    operator. 
Precaution - Reminds the user to pay close attention to device operation, failure of which may cause abnormal function of the instrument. 

Notice - Informs the user of other important information by suggestion, requirement and supplement.

 

Warning 

  Please read this manual carefully before using this device. The user must check that the equipment functions safely and ensure that it is in proper working condition before being used. 

  Do not use the pulse oximeter in an explosive atmosphere. 

  Do not use the pulse oximeter in an MRI or CT environment 

  The pulse oximeter is indicted for use by medical professionals only 

  The device has no SpO

2

 alarms or PR alarms, it is not for continuous monitoring, as indicated by the symbol. 

  Prolonged  use of the probe/sensor or the patient’s condition may require changing the sensor site periodically. Change the sensor site and check skin integrity, circulatory status, and correct 

alignment at least every 4 hours. Prolonged use may cause blisters, skin deterioration, and discomfort. 

  When connecting this monitor to any instrument, verify proper  operation before  clinical use. Refer to  the instrument’s  user  manual for full instructions. The equipment  connected to the pulse 

oximeter’s data interface must be certified according to the respective IEC standards, i.e., IEC950 for data processing equipment or IEC 601-1 for medical electrical equipment. All combinations of 
equipment must be in compliance with IEC601-1-1 systems requirements.   

Содержание VPOD-H

Страница 1: ...ationwide Medicare approved Independent Diagnostic Testing Facility The VirtuOx Total Solution consists of our flagship Overnight Oximetry Testing platform VirtuOxTM now at NO CHARGE combined with our...

Страница 2: ...es depending on hemoglobin concentration The amount of light absorption at each light frequency is dependent on the degree of oxygenation of hemoglobin within the tissues The microprocessor can select...

Страница 3: ...It can be eliminated by covering each site with opaque material Optical cross talk may adversely affect the accuracy of the SpO2 readings Obstructions or dirt on the sensor s red light or detector ma...

Страница 4: ...the oximeter sensor probe is kept as still as possible 2 4 2 Brightness adjustment When you press the function key left key for more than one second the brightness level headed with Br will be shown...

Страница 5: ...tient motion conditions 3 2 Mode Introduction Power On Measurement and operation can be done normally There are three display modes Measure mode Information display mode and Trouble display mode 1 Dis...

Страница 6: ...ox software and a special data cable As for detailed setup and operation please refer to the Virtuox website www virtuox net Note Virtuox can be obtained at no charge with the purchase of this device...

Страница 7: ...with the operator s manual e The oximeter is installed or connected with such external device without our company permission as printer computer netline and lead to oximeter failure Our company will c...

Страница 8: ...rm Alarm Probe off Finger out Low battery Modes Visual Information Display Type OLED double color Parameters SpO2 PR Pleth waveform Pleth bar Mode 3 display modes Record Patient ID 10 patients Data re...

Страница 9: ...broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If...

Страница 10: ...Ver1 2 VPOD OPERATOR S MANUAL 9 objects and people...

Отзывы: