Mechanics
Motorized lock with two cylindrical horizontal deadbolts.
Controlled opening.
Emergency mechanical opening with special profile disc safety cylinder
allowing to open the safe in any case of anomalous block.
Easy accessible battery holder.
Replaceable door and door back cover.
Electronics
12 key keypad with Braille reference and sound confirmation (the non-
sighted are able to recognize the exact layout of the keys) and with 6
digit alphanumerical display.
6 digit Guest Code.
6 digit Multilevel Master Code (up to 6 different Area Codes).
Needs Guest Code for closing.
Resident codes in NON-VOLATILE memory: stored codes remain in
memory even if batteries are removed.
Electronic anti-theft block of 7 minutes after 5 consecutive wrong codes
are entered.
Audit Trial of the last 150 operations.
Electronic anti-theft block of 10 minutes after 15 operations done in 5
minutes to avoid Audit Trial manumissions.
Low consumption electronic board protected from any break-in attempts
performed with electrical shocks.
Audio-visual warning of low battery on display.
Power supply
4 x 1,5V AA LR6 alkaline batteries (already included). Thanks to the
electronic board high engineering level it is possible to make more than
10,000 operations with 1 set of 4 alkaline batteries. Special long life
batteries can be used, thus increasing even more the autonomy of the safe.
Optional power supply from the electrical mains.
Environmental conditions:
Working temperature ......................... 0 / +45 °C
Relative humidity (with no dew) .......... 0 / 90 %RH
Optional
Activating kit for renting option.
220 Volts converter for power supply option.
Recharging kit for laptops and mobile phones.
Emergency opening operated with one Electronic Key.
Hand-held printer for Audit Trial printing.
Maxi 4875 and Midi 4845
Installation and User Manual
Page 4 of 40
2 INSTALLATION
The safe must be installed by qualified personnel only
. In order to
make your safe work properly, please follow carefully the following
instructions.
Maxi 4870 and Midi 4840 safes could be wall-mounted using dowels or could
be installed on a plane surface (for instance inside a piece of furniture –
suggested installation) using fixing bracket and bolts (see Fig. 2 next page)
or using screws for wood (if the piece of furniture is thick enough). Fixing
elements (dowels, bracket, bolts) are not included.
For the installation of the safe, choose an adequate place with the following
characteristics.
Installation surface
It should be a regular and plane surface. Do not install the safe on a
slanting or unstable position like tripods, shelves or tables.
Temperature
Above 0°C and below 45°C. Do not install the safe near heat sources such
as radiators, stoves, etc.
Humidity
Relative humidity without dew below 90% RH. Do not install the safe near
basins, wash-basins, etc. Absolutely avoid pouring liquids on the safe.
If the relative humidity of the room where the safe is installed was too
high (for instance after the starting up of the heating system, when the
room was previously cold), moisture condensation should appear inside
the safe and the safe might not work rightly. In such cases, do not use the
safe for some hours, then try again.