Notes: 1) The addition of chlorine (bleach) to a hot water tank that has in the past been fed with untreated raw water with 

high levels of other contaminants (iron, manganese, hydrogen sulphide, organics, etc.) will result in oxidation of 
these contaminants and may require repeated flushing of the hot water tank. This contingency must be dealt with 
independently under the start-up procedure for any other conditioners that may form a part of the pre-treatment 
for the UV unit.

2) The above disinfection procedure will result in a massive chlorine residual far in excess of the 0.5 to 1.0 mg/L 

typically present in municipally chlorinated water and of a magnitude consistent with the minimum 50 mg/L 
chlorine solution recommended for the disinfection of distribution systems known to be contaminated. Do not 
consume water until complete system has been flushed

.

9

1

2

•   

With all faucets closed, 
remove sump housing using 
sump wrench. 

10

10

1

2

•   

Reinstall the cartridge into 
sump housing and connect to 
the unit.

•   

Flush all water outlets until 
bleach can no longer be 
smelled (at least 5 minutes).

11

•   

Press the pressure button to 
purge air and to complete the 
disinfection procedure.

Содержание VH200-F10

Страница 1: ...tario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com Models VH200 F10 VH410 F20 Owner s Manual P...

Страница 2: ...y should you insist on genuine factory supplied VIQUA replacement lamps Use of widely available non genuine replacement lamps has been shown to damage the control module of VIQUA UV disinfection equip...

Страница 3: ...started Warning This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm DANGER Failure to follow these instructions will resul...

Страница 4: ...o clean up a broken lamp as this may scatter the spilled mercury Obey local regulations and guidelines for the removal and disposal of mercury waste NOTICE The UV lamp inside the disinfection system i...

Страница 5: ...tems 5 IEC Replacement Power Cords For VIQUA ICE Controller Sold Separately 260010 NORTH AMERICAN NEMA 5 15P 3 PRONG GROUNDED 602637 CONTINENTAL EUROPEAN CEE 7 7 2 PIN WITH GROUND SCHUKO 260012 UK VER...

Страница 6: ...shows the installation of a typical drinking water system and the related components that may be used for the installation The use of a bypass assembly is recommended in case the system requires off...

Страница 7: ...e system to the wall with appropriate lag bolts not supplied through the two mounting holes located on the metal bracket The use of a flow restrictor device is recommended when installing your system...

Страница 8: ...e in the house for a minute to flush out the warm water 3 2 Disinfection Procedure UV disinfection is a physical process and does not add any potentially harmful chemicals to the water As UV does not...

Страница 9: ...e above disinfection procedure will result in a massive chlorine residual far in excess of the 0 5 to 1 0 mg L typically present in municipally chlorinated water and of a magnitude consistent with the...

Страница 10: ...or UV lamp disposal Do not use water during replacement of UV lamp 1 Shut off the water line to chamber and release system pressure before servicing 2 0 30 15 45 10 mins Disconnect main power source a...

Страница 11: ...quartz sleeve Remove the quartz sleeve 4 Clean the quartz sleeve with a cloth soaked in CLR vinegar or some other mild acid and then rinse with water Note If sleeve cannot be cleaned completely or it...

Страница 12: ...a small bucket under the system to catch any water Procedure 1 Shut off the water flow to the unit depress pressure relief button on top of the filter head to relieve pressure in the filter Refer to...

Страница 13: ...hem P N OR40 50 5 Ensure o rings are liberally coated with a silicone based lubricant 6 Install the new cartridge in the reverse procedure as stated above turning the collar clockwise until the sump i...

Страница 14: ...tting Lamp Life Refer to Section 4 1 Note Even though the alarm on the system can be deferred for a period of time it is important to address each and every alarm condition as they are indicating that...

Страница 15: ...ng seal on retaining nut Ensure O ring is in place check for cuts or abrasions clean O ring moisten with water lubricant and re install replace if necessary Refer to Section 2 for part number Condensa...

Страница 16: ...Manufacturer s Dose Flow Chart 16 Section 7 Manufacturer s Dose Flow Chart Not performance tested or certified by NSF Figure 9 Dose Flow Chart VH200 F10 VH410 F20 VIQUA Standard 32...

Страница 17: ...lbs 13 2 kg 29 lbs Electrical Voltage 100 240 V 50 60 Hz 100 240 V 50 60 Hz Max Current 1 5 Amp 1 5 Amp Power Consumption 35 W 60W Lamp Watts 27 W 45W Maximum Operating Pressure 100 psi 689 kPa 100 p...

Страница 18: ...Hardware Components VIQUA warrants the electrical controller and hardware components to be free from defects in material and workmanship for a period of three 3 years from the date of purchase During...

Страница 19: ...425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com...

Отзывы: