Maintenance

10

Section 4

Maintenance

4.1 Replacing UV Lamp

Lamp replacement is a quick and simple procedure requiring no special tools. The UV lamp must be replaced after 9000 
hours of continuous operation (approximately one year) in order to ensure adequate disinfection.

Procedure:

W A R N I N G

  •

Always disconnect power before performing any work on the disinfection system.

  •

Always shut-off water flow and release water pressure before servicing.

  •

Regularly inspect your disinfection system to ensure that the power indicators are on and no alarms are present.

  •

Replace the UV lamp annually (or biennially if seasonal home use) to ensure maximum disinfection.

  •

Always drain the chamber when closing a seasonal home or leaving the unit in an area subject to freezing temperatures.

N O T I C E

  •

Reset lamp life timer after lamp replacement. Refer to 

Section 5.1.3

. Refer to 

www.lamprecycle.org

 for UV lamp disposal.

  •

Do not use water during replacement of UV lamp.

1

•   

Shut off the water line to 
chamber and release system 
pressure before servicing.

2

0

30

15

45

10 mins

•   

Disconnect main power 
source and allow the unit to 
cool for 10 minutes.

3

1

2

•   

Remove the lamp connector 
by squeezing the plastic 
locking tabs on the side of the 
connector.

4

Hg

UV

•   

Remove the lamp in upward 
direction from the chamber 
and lamp connector base.

•   

Always hold the lamp at the 
ceramic ends.

5

Hg

UV

1

2

•   

Insert the new lamp fully into 
the chamber leaving about 
two inches of the lamp 
protruding from the chamber.

6

4

2

3

1

•   

Attach the connector to the 
lamp. Note that the connector 
will only allow correct 
installation in one position. 

7

1

2

click

•   

Push the lamp connector 
against lamp connector base 
together until an audible click 
is heard.

8

•   

Hold down the timer reset 
button and reapply power to 
the controller until you see 

, then release timer 

reset button.

•   

A 5 second delay will occur 
until you hear an audible tone 
and LED display will read 
once again 

.

•   

Re-pressurize the system to 
check for leaks.

Содержание VH200-F10

Страница 1: ...tario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com Models VH200 F10 VH410 F20 Owner s Manual P...

Страница 2: ...y should you insist on genuine factory supplied VIQUA replacement lamps Use of widely available non genuine replacement lamps has been shown to damage the control module of VIQUA UV disinfection equip...

Страница 3: ...started Warning This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm DANGER Failure to follow these instructions will resul...

Страница 4: ...o clean up a broken lamp as this may scatter the spilled mercury Obey local regulations and guidelines for the removal and disposal of mercury waste NOTICE The UV lamp inside the disinfection system i...

Страница 5: ...tems 5 IEC Replacement Power Cords For VIQUA ICE Controller Sold Separately 260010 NORTH AMERICAN NEMA 5 15P 3 PRONG GROUNDED 602637 CONTINENTAL EUROPEAN CEE 7 7 2 PIN WITH GROUND SCHUKO 260012 UK VER...

Страница 6: ...shows the installation of a typical drinking water system and the related components that may be used for the installation The use of a bypass assembly is recommended in case the system requires off...

Страница 7: ...e system to the wall with appropriate lag bolts not supplied through the two mounting holes located on the metal bracket The use of a flow restrictor device is recommended when installing your system...

Страница 8: ...e in the house for a minute to flush out the warm water 3 2 Disinfection Procedure UV disinfection is a physical process and does not add any potentially harmful chemicals to the water As UV does not...

Страница 9: ...e above disinfection procedure will result in a massive chlorine residual far in excess of the 0 5 to 1 0 mg L typically present in municipally chlorinated water and of a magnitude consistent with the...

Страница 10: ...or UV lamp disposal Do not use water during replacement of UV lamp 1 Shut off the water line to chamber and release system pressure before servicing 2 0 30 15 45 10 mins Disconnect main power source a...

Страница 11: ...quartz sleeve Remove the quartz sleeve 4 Clean the quartz sleeve with a cloth soaked in CLR vinegar or some other mild acid and then rinse with water Note If sleeve cannot be cleaned completely or it...

Страница 12: ...a small bucket under the system to catch any water Procedure 1 Shut off the water flow to the unit depress pressure relief button on top of the filter head to relieve pressure in the filter Refer to...

Страница 13: ...hem P N OR40 50 5 Ensure o rings are liberally coated with a silicone based lubricant 6 Install the new cartridge in the reverse procedure as stated above turning the collar clockwise until the sump i...

Страница 14: ...tting Lamp Life Refer to Section 4 1 Note Even though the alarm on the system can be deferred for a period of time it is important to address each and every alarm condition as they are indicating that...

Страница 15: ...ng seal on retaining nut Ensure O ring is in place check for cuts or abrasions clean O ring moisten with water lubricant and re install replace if necessary Refer to Section 2 for part number Condensa...

Страница 16: ...Manufacturer s Dose Flow Chart 16 Section 7 Manufacturer s Dose Flow Chart Not performance tested or certified by NSF Figure 9 Dose Flow Chart VH200 F10 VH410 F20 VIQUA Standard 32...

Страница 17: ...lbs 13 2 kg 29 lbs Electrical Voltage 100 240 V 50 60 Hz 100 240 V 50 60 Hz Max Current 1 5 Amp 1 5 Amp Power Consumption 35 W 60W Lamp Watts 27 W 45W Maximum Operating Pressure 100 psi 689 kPa 100 p...

Страница 18: ...Hardware Components VIQUA warrants the electrical controller and hardware components to be free from defects in material and workmanship for a period of three 3 years from the date of purchase During...

Страница 19: ...425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com...

Отзывы: