 Safety Instructions:

  

WARNING

 - to guard against injury, basic safety precautions should be 

observed, including the following:

1. 

 READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

2. 

 GROUNDING

 - 

This product must be grounded. If it should malfunction 

or breakdown, grounding provides a path of least resistance for electric 

current to reduce the risk of electrical shock. This system is equipped 

with a cord having an equipment-grounding conductor and a grounding 

plug. The plug must be plugged into an appropriate outlet that is properly 

installed and grounded in accordance with all local codes and ordinances.

 

 DANGER – Improper connection of the equipment-grounding conductor 

can result in a risk of electrocution. Check with a qualified electrician or 

service personnel if you are in doubt as to whether the outlet is properly 

grounded. Do not modify the plug provided with this system – if it will not 

fit the outlet, have a proper outlet installed by a qualified electrician. Do 

not use any type of adapter with this system.

3. 

 GROUND FAULT CIRCUIT INTERRUPTER PROTECTION - 

To comply 

with the National Electrical Code (NFPA 70) and to provide additional 

protection from the risk of electric shock, this system should only 

be connected to a properly grounded, grounding-type power supply 

receptacle that is protected by a Ground Fault Circuit Interrupter (GFCI). 

Inspect operation of GFCI as per manufacturers suggested maintenance 

schedule.

4. 

CAUTION

 - Always disconnect power before servicing.

5.  

DANGER

 - To avoid possible electric shock, special care should be taken 

since water is present near electrical equipment. Unless a situation is 

encountered that is explicitly addressed by the provided maintenance 

and troubleshooting sections, do not attempt repairs yourself, refer to an 

authorized service facility.

6.   Carefully examine the disinfection system after installation. It should not 

be plugged in if there is water on parts not intended to be wet such as, 

the ballast or lamp connector.

7.    Do not operate the disinfection system if it has a damaged cord or plug, if 

it is malfunctioning or if it has been dropped or damaged in any manner.

8.   Always unplug the disinfection system before performing any cleaning 

or maintenance activities. Never yank the cord to remove from an outlet; 

grasp the wall plug and pull to disconnect.

 

Note:

    The UV lamps inside of the disinfection system are rated at an effective life of  

approximately 9000 hours.  To ensure continuous protection, replace the UV 

lamps annually.

2

WARNING

 - Always shut-off water flow and release water pressure 

before servicing.

Содержание SHF-140

Страница 1: ...FM 140 SHFM 140 2 SHF 180 SHF 180 2 SHFM 180 SHFM 180 2 425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069...

Страница 2: ...fe coated for stability longer life and increased efficiency Even lamps that look the same will not perform the same Get water confidence with genuine lamps proven to disinfect over their entire lifet...

Страница 3: ...ou have taken the first step in ensuring the safety of your water supply by using a totally non intrusive physical disinfection method Your Sterilight system uses the most advanced UV technology on th...

Страница 4: ...ce on UV Chamber unless UV chamber has been isolated and depressurized Never service UV Lamps Sleeves or associated hardware until depressurization of UV chamber has been confirmed Hot chamber Allow U...

Страница 5: ...gile Eye Protection WEEE waste electrical or electronic equipment This symbol indicates that you should not discard wasted electrical or electronic equipment WEEE in the trash For proper disposal cont...

Страница 6: ...d separately 260192 R NORTH AMERICAN NEMA 5 15P 3 PRONG GROUNDED 260198 R CONTINENTAL EUROPEAN CEE 7 7 2 PIN WITH GROUND SCHUKO 260193 R NO CONNECTOR 3 WIRE BARE LEADS 214 fused quartz sleeves with fi...

Страница 7: ...is system should only be connected to a properly grounded grounding type power supply receptacle that is protected by a Ground Fault Circuit Interrupter GFCI Inspect operation of GFCI as per manufactu...

Страница 8: ...accept the plug from this system Use only extension cords that are intended for outdoor use Use only extension cords having an electrical rating not less than the rating of the system A cord rated for...

Страница 9: ...e must be connected to a grounded receptacle and the lamp connector ground wire connected to the stainless steel reactor chamber The disinfection system is designed to be mounted horizontally within t...

Страница 10: ...returned to service Please refer to the complete disinfection procedure as outlined on page 7 of this document If the water is to be consumed while the system is off line the water must be boiled for...

Страница 11: ...provided Figure 1E 5 Install the UV lamps and UV sensor as outlined on pages 8 10 6 When all plumbing connections are made slowly turn on the water supply and check for leaks The most likely cause fo...

Страница 12: ...it is strongly recommended that the entire distribution system located after the UV be chemically disinfected to ensure that the pipework is free from any bacteriological contaminants The disinfectio...

Страница 13: ...om the connector simply slide the two apart Avoid touching the lamp on the glass portion Handling the lamp at the ceramic ends is acceptable however if you must touch the lamp glass please use gloves...

Страница 14: ...e retaining nuts by turning counter clockwise Figure 3a Drain chamber through drain port Grasp the quartz sleeve and fully remove from the reactor chamber Remove both o rings As with the lamp make sur...

Страница 15: ...sensor Disconnect the UV sensor from the Hi Flo Monitored BA ICE M HF controller by disconnecting the sensor cable turning the collar counter clockwise Figure 4B To remove the sensor grasp the body of...

Страница 16: ...ired lamp from the reactor chamber dispose of in accordance with local or regional laws and regulations 3 install new UV lamp and connect it to lamp connector refer to page 8 4 replace lamp connector...

Страница 17: ...quired to Indicates the UV level is nearing the point of unsafe UV intensity UV system should be immediately serviced Indicates the UV level has now reached a level that is unsafe At this level the wa...

Страница 18: ...sh button SWITCH two times in succession and follow steps as outline on page 11 regarding the operation of this feature 4 Lamp failure blank screen Please refer to page 10 for explanation of this feat...

Страница 19: ...This Y cable comes with 20 meters 65 of cable for the 4 20 mA signal To install first remove the existing sensor cable from the HF Enclosure Figure 5B and affix the new Y cable Figure 5C Next attach...

Страница 20: ...quent use of water run water until it returns to ambient temperature install temperature management valve Water Appears Milky Caused by air in the water lines run water until air is purged Unit Leakin...

Страница 21: ...quartz sleeves and sensor eye LED flashing A2 and then back to UV level low UV alarm deferral has been activated UV level has dropped below 50 and the audible alarm has been muted by pressing the res...

Страница 22: ...68 lbs 31 8 kg 70 lbs 35 5 kg 78 lbs 36 4 kg 80 lbs Electrical Voltage 100 240V 50 60Hz 100 240V 50 60Hz 100 240V 50 60Hz 100 240V 50 60Hz Power Consumption 350 W 350 W 440 W 440 W Lamp Watts 300 W 30...

Страница 23: ...t the problem and identify a solution Please have available the model number system type the date of purchase the name of the dealer from whom you purchased your Sterilight product the source dealer a...

Страница 24: ...under these warranties will be covered under warranty up to the end of the warranty period applicable to the original part The above warranties do not include the cost of shipping and handling of retu...

Отзывы:

Похожие инструкции для SHF-140