Troubleshooting

13

5.2 12VDC Systems Incorporating BA-RO/P/12 Controller

Section 6

Troubleshooting

Green LED indicates UV lamp “ON”.

Symptom

Possible Causes

Solutions

Pressure Drop

Sediment pre-filter clogged

Replace filter cartridge with appropriate 5 micron cartridge.

Note: 

Check source water supply as fluctuations may occur in source pressure.

Flow regulator

Flow regulator will result in pressure drop when approaching full flow.

High Bacteria
Counts

Quartz sleeve is stained or dirty

Clean sleeve with scale cleaner and eliminate source of staining problem (ie. soften hard water, 
refer to 

Section 4.2

.

Change in feed water quality

Have source water tested to ensure that water quality is still within allowable limits for this 
system.

Contamination in water lines after UV 
system (eg. power failures, plumbing 

Disinfection system must have a bacterial free distribution system to work effectively. Refer to 

Section 3.2

Possible break-through of sediment 
through pre-filter

Have source water tested for turbidity - may need stepped filtration in order to catch all 
sediment entering water system (20 micron filter followed by a 5 micron filter followed by UV 

Heated Product 
Water

Common problem caused by infrequent 
use of water

Run water until it returns to ambient temperature.

Water Appears 
Milky

Caused by air in the water lines

Run water until air is purged.

Unit Leaking Water

Problem with O-ring seal (on retaining 
nut and/or UV sensor)

Ensure O-ring is in place, check for cuts or abrasions, clean O-ring, moisten with water/ 
lubricant and re-install, replace if necessary (410867).

Condensation on UV chamber caused 
by excessive humidity & cold water

Check location of disinfection system and control humidity.

Inadequate inlet/outlet port connections

Check thread connections, reseal with Teflon

®

 tape and re-tighten.

System Shutting 
Down Intermittently

Interrupted controller

  •

Ensure system has been installed on its own circuit, as other equipment may be drawing 
power away from UV (ie. pump or fridge).

  •

UV system should not be installed on a circuit which is incorporated into a light switch.

UV lamp Failure 
Alarm on - New 
lamp

Loose connection between UV lamp 
and connector

Disconnect UV lamp from connector and reconnect, ensuring that a tight fit is accomplished

Moisture build up in connector may 
keep UV lamp and connector from 
making a solid connection

Eliminate chance of any moisture getting to the connector and/or lamp pins

DISPLAY FAULT MODES

LED display reads “A3”

  •

UV lamp life expired - countdown is at “0” days. Refer to 

Section 5.1.2

, Understanding your A3 Code.

  •

Press reset button for a deferred alarm, replace UV lamp

LED display is blank

  •

Controller is in UV lamp failure mode. Refer to 

Section 5.1.5

, UV Lamp Failure. Replace UV Lamp, refer to 

Section 4.1

.

  •

Power system down, allowing it to reset itself; apply power in order to confirm that the controller is able to power UV lamp

  •

Check to see if there is sufficient power to the UV system

Green LED off (12 VDC 

only)

  •

UV lamp failure. Replace UV Lamp, refer to 

Section 4.1

.

  •

No input voltage to controller

Содержание S2Q-P/12VDC

Страница 1: ...f 1 519 763 5069 e mail info viqua com www viqua com Models S1Q PA S2Q PA S5Q PA S8Q PA S2Q P 12VDC S5Q P 12VDC NSF Standard 55 Class B Validated Models SV5Q PA SV8Q PA Owner s Manual Powered by Syste...

Страница 2: ...y should you insist on genuine factory supplied VIQUA replacement lamps Use of widely available non genuine replacement lamps has been shown to damage the control module of VIQUA UV disinfection equip...

Страница 3: ...started Warning This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm DANGER Failure to follow these instructions will resul...

Страница 4: ...d inhalation or ingestion of the debris and avoid exposure to eyes and skin Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury Obey local regulations and guid...

Страница 5: ...r long consistent life 9000 hours S287RL S1Q PA S330RL S2Q PA S463RL S5Q PA SV5Q PA S810RL S8Q PA SV8Q PA 7 Controller for 100 240V models only BA ICE S S1Q PA S2Q PA S5Q PA S8Q PA SV5Q PA SV8Q PA 8 C...

Страница 6: ...it may be exposed to the weather Install the disinfection system on cold water line only before any branched lines A 5 micron sediment filter must precede the disinfection system Ideally the disinfect...

Страница 7: ...tain the manufacturers rated flow The flow restrictor should be installed on the outlet port and is designed to be installed in one direction only Ensure that the flow of the water matches the flow di...

Страница 8: ...a leak shut water off drain cell remove the retaining nut wipe the O ring and threads Clean and re install 7 Once it is determined that there are no leaks plug the system into the ground fault interru...

Страница 9: ...ocedure for any other conditioners that may form a part of the pre treatment for the UV unit 2 The above disinfection procedure will result in a massive chlorine residual far in excess of the 0 5 to 1...

Страница 10: ...org for UV lamp disposal DO NOT use water during replacement of UV lamp 1 Shut off the water line to chamber and release system pressure before servicing 2 0 30 15 45 10 mins Disconnect main power sou...

Страница 11: ...ring 4 Carefully remove O ring adhering to the quartz sleeve Remove the quartz sleeve 5 Mild Acid Clean the quartz sleeve with a cloth soaked in CLR vinegar or some other mild acid and then rinse wit...

Страница 12: ...refer to Section 4 1 5 1 3 Resetting UV lamp Life Refer to Section 4 1 Note Even though the alarm on the system can be deferred for a period of time it is important to address each and every alarm co...

Страница 13: ...d or UV sensor Ensure O ring is in place check for cuts or abrasions clean O ring moisten with water lubricant and re install replace if necessary 410867 Condensation on UV chamber caused by excessive...

Страница 14: ...1 cm x 6 4 cm 7 3 x 3 2 x 2 5 18 6 cm x 8 1 cm x 6 4 cm 7 3 x 3 2 x 2 5 Controller 12 VDC 13 5 cm x 4 3 cm x 5 8 cm 5 3 x 1 7 x 2 3 13 5 cm x 4 3 cm x 5 8 cm 5 3 x 1 7 x 2 3 Inlet Outlet Port Size1 1...

Страница 15: ...Hardware Components VIQUA warrants the electrical controller and hardware components to be free from defects in material and workmanship for a period of three 3 years from the date of purchase During...

Страница 16: ...425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com...

Отзывы: