Safety Information

3

Section 1

Safety Information

These are the original instructions. Please read this entire manual before operating this equipment. Pay attention to all 

danger, warning, and caution statements in this manual. Failure to do so could result in serious personal injury or damage to 

the equipment.
Make sure that the protection provided by this equipment is not impaired. DO NOT use or install this equipment in any 

manner other than that specified in the installation manual.

1.1 Potential Hazards:

Read all labels and tags attached to the system. Personal injury or damage to the system could occur if not observed.

1.2 Safety Precautions:

Waste electrical and electronic equipment (WEEE). This symbol 
indicates that you should not discard wasted electrical or electronic 
equipment (WEEE) in the trash. For proper disposal, contact your local 
recycling/reuse or hazardous waste center.

This symbol indicates not to store any combustible or flammable 
material close to the system.

This symbol indicates there is Mercury present.

This symbol indicates that the contents of the transport package are 
fragile and the package should be handled with care.

This is the safety alert symbol. Obey all safety messages that follow 
this symbol to avoid potential injury. When on the equipment, refer to 
the Operational and Maintenance manual for additional safety 
information.

This symbol indicates safety glasses with side protection is required for 
protection against UV exposure.

This symbol indicates a risk of electrical shock and/or electrocution 
exists.

This symbol indicates gloves must be worn.

This symbol indicates the marked equipment may contain a 
component that can eject forcibly. Obey all procedures to safely 
depressurize.

This symbol indicates safety boots must be worn.

This symbol indicates the system is under pressure.

This symbol indicates the operator must read all available 
documentation to perform required procedures.

This symbol indicates there is a potential UV hazard. Proper protection 
must be worn.

This symbol indicates the plumber must use copper piping.

This symbol indicates the marked item could be hot and should not be 
touched without care.

This symbol indicates that the system should only be connected to a 
properly grounded, grounding-type controller receptacle that is 
protected by a Ground Fault Circuit Interrupter (GFCI).

This symbol indicates there is a potential for VERY hot water when 
flow is started.

Warning:

 This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.

D A N G E R

Failure to follow these instructions will result in serious injury or death.

Electric Shock:

 To avoid possible electric shock, special care should be taken since water is present near the electrical equipment. Unless a

situation is encountered that is explicitly addressed by the provided maintenance and troubleshooting sections, DO NOT attempt repairs yourself,

refer to an authorized service facility.

GROUNDING: 

This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric

current to reduce the risk of electrical shock. This system is equipped with a cord having an equipment-grounding conductor and a grounding plug.

The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Improper connection of the equipment-grounding conductor can result in a risk of electrocution. Check with a qualified electrician or service

personnel if you are in doubt as to whether the outlet is properly grounded. DO NOT modify the plug provided with this system – if it does not fit in

the outlet, have a proper outlet installed by a qualified electrician. DO NOT use any type of adapter with this system.

GROUND FAULT CIRCUIT INTERRUPTER PROTECTION

: To comply with the National Electrical Code (NFPA 70) and to provide additional

protection from the risk of electric shock, this system should only be connected to a properly grounded, grounding-type controller receptacle that is

protected by a Ground Fault Circuit Interrupter (GFCI) or to a residual current device (RCD) having a rated residual operating current not

exceeding 30 mA. Inspect operation of GFCI as per manufacturer’s suggested maintenance schedule.

DO NOT operate the disinfection system if it has a damaged cord or plug, if it is malfunctioning or if it has been dropped or damaged in any

manner.

DO NOT use this disinfection system for other than intended use (potable water applications). The use of attachments not recommended or sold by 

the manufacturer / distributor may cause an unsafe condition.

DO NOT install this disinfection system where it will be exposed to the weather or to temperatures below freezing.

DO NOT store this disinfection system where it will be exposed to the weather.

DO NOT store this disinfection system where it will be exposed to temperatures below freezing unless all water has been drained from it and the

water supply has been disconnected.

Hg

UV

Cu

Содержание S2Q-P/12VDC

Страница 1: ...f 1 519 763 5069 e mail info viqua com www viqua com Models S1Q PA S2Q PA S5Q PA S8Q PA S2Q P 12VDC S5Q P 12VDC NSF Standard 55 Class B Validated Models SV5Q PA SV8Q PA Owner s Manual Powered by Syste...

Страница 2: ...y should you insist on genuine factory supplied VIQUA replacement lamps Use of widely available non genuine replacement lamps has been shown to damage the control module of VIQUA UV disinfection equip...

Страница 3: ...started Warning This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm DANGER Failure to follow these instructions will resul...

Страница 4: ...d inhalation or ingestion of the debris and avoid exposure to eyes and skin Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury Obey local regulations and guid...

Страница 5: ...r long consistent life 9000 hours S287RL S1Q PA S330RL S2Q PA S463RL S5Q PA SV5Q PA S810RL S8Q PA SV8Q PA 7 Controller for 100 240V models only BA ICE S S1Q PA S2Q PA S5Q PA S8Q PA SV5Q PA SV8Q PA 8 C...

Страница 6: ...it may be exposed to the weather Install the disinfection system on cold water line only before any branched lines A 5 micron sediment filter must precede the disinfection system Ideally the disinfect...

Страница 7: ...tain the manufacturers rated flow The flow restrictor should be installed on the outlet port and is designed to be installed in one direction only Ensure that the flow of the water matches the flow di...

Страница 8: ...a leak shut water off drain cell remove the retaining nut wipe the O ring and threads Clean and re install 7 Once it is determined that there are no leaks plug the system into the ground fault interru...

Страница 9: ...ocedure for any other conditioners that may form a part of the pre treatment for the UV unit 2 The above disinfection procedure will result in a massive chlorine residual far in excess of the 0 5 to 1...

Страница 10: ...org for UV lamp disposal DO NOT use water during replacement of UV lamp 1 Shut off the water line to chamber and release system pressure before servicing 2 0 30 15 45 10 mins Disconnect main power sou...

Страница 11: ...ring 4 Carefully remove O ring adhering to the quartz sleeve Remove the quartz sleeve 5 Mild Acid Clean the quartz sleeve with a cloth soaked in CLR vinegar or some other mild acid and then rinse wit...

Страница 12: ...refer to Section 4 1 5 1 3 Resetting UV lamp Life Refer to Section 4 1 Note Even though the alarm on the system can be deferred for a period of time it is important to address each and every alarm co...

Страница 13: ...d or UV sensor Ensure O ring is in place check for cuts or abrasions clean O ring moisten with water lubricant and re install replace if necessary 410867 Condensation on UV chamber caused by excessive...

Страница 14: ...1 cm x 6 4 cm 7 3 x 3 2 x 2 5 18 6 cm x 8 1 cm x 6 4 cm 7 3 x 3 2 x 2 5 Controller 12 VDC 13 5 cm x 4 3 cm x 5 8 cm 5 3 x 1 7 x 2 3 13 5 cm x 4 3 cm x 5 8 cm 5 3 x 1 7 x 2 3 Inlet Outlet Port Size1 1...

Страница 15: ...Hardware Components VIQUA warrants the electrical controller and hardware components to be free from defects in material and workmanship for a period of three 3 years from the date of purchase During...

Страница 16: ...425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com...