Manufacturer’s Dose Flow Chart
14
Section 7
Manufacturer’s Dose Flow Chart
Section 8
Specifications: Standard and Validated
Model
S1Q-PA
S2Q-P/12VDC/
S2Q-PA
S5Q-P/12VDC/
S5Q-PA/SV5Q-PA
*
S8Q-PA/
SV8Q-PA
*
Flow Ra
te
*
NSF Class B Certified
16mJ/cm
2
@ 70% UVT
-
-
3.6 gpm (13.6 lpm) (0.8 m
3
/
hr)
7 gpm (26.5 lpm) (1.6 m
3
/
hr)
US Public Health 16mJ/cm
2
@ 95% UVT
3.5 gpm (13 lpm) (0.8 m
3
/
hr)
5 gpm (19 lpm) (1.1 m
3
/hr)
11 gpm (42 lpm) (2.5 m
3
/hr)
20 gpm (75 lpm) (4.5 m
3
/hr)
VIQUA Standard 30 mJ/cm
2
@ 95% UVT
2 gpm (7 lpm) (0.4 m
3
/hr)
3 gpm (11 lpm) (0.7 m
3
/hr)
6 gpm (23 lpm) (1.4 m
3
/hr)
10 gpm (38 lpm) (2.3 m
3
/hr)
NSF/EPA 40mJ/cm
2
@ 95%
UVT
1.5 gpm (5 lpm) (0.3 m
3
/hr)
2 gpm (7 lpm) (0.4 m
3
/hr)
4.5 gpm (17 lpm) (1.0 m
3
/
hr)
8 gpm (29 lpm) (1.8 m
3
/hr)
Dimensions
Chamber
38.1 x 6.4 cm (15" x 2.5")
43.2 cm x 6.4 cm (17” x
2.5”)
56 cm x 6.4 cm (22” x 2.5”)
90 cm x 6.4 cm (35” x 2.5”)
Controller 100-250 VAC
18.6 cm x 8.1 cm x 6.4 cm
(7.3” x 3.2” x 2.5”)
18.6 cm x 8.1 cm x 6.4 cm
(7.3” x 3.2” x 2.5”)
18.6 cm x 8.1 cm x 6.4 cm
(7.3” x 3.2” x 2.5”)
18.6 cm x 8.1 cm x 6.4 cm
(7.3” x 3.2” x 2.5”)
Controller 12 VDC
-
13.5 cm x 4.3 cm x 5.8 cm
(5.3” x 1.7” x 2.3”)
13.5 cm x 4.3 cm x 5.8 cm
(5.3” x 1.7” x 2.3”)
-
Inlet/Outlet Port Size
1
1/4” MNPT
1/2” MNPT
3/4” MNPT”
3/4” MNPT
Shipping Weight
2.7 kg (6 lbs)
2.7 kg (6 lbs)
2.7 kg (6 lbs)
4.5 kg (10 lbs)
Electrical
Voltage
2
100-240 V /50/60 Hz
100-240 V /
50/60 Hz
12 VDC
100-240 V /
50/60 Hz
12 VDC
100-240 V / 50/60 Hz
Max. Current
0.6 Amp
0.6 Amp
1.8 Amp
0.6 Amp
1.8 Amp
0.6 Amp
Power Consumption
19 W
22 W
20 W
30 W
27 W
46 W
UV lamp Watts
14 W
17 W
15 W
25 W
20 W
37 W
Maximum Operating Pressure
125 psi (861 kPa)
125 psi (861 kPa)
125psi (861 kPa)
125 psi (861 kPa)
Minimum Operating Pressure
15 psi (103 kPa)
15 psi (103 kPa)
15psi (103 kPa)
15 psi (103 kPa)
Ambient Water Temperature
2-40 ºC (36-104 ºF)
2-40 ºC (36-104 ºF)
2-40 ºC (36-104 ºF)
2-40 ºC (36-104 ºF)
UV Lamp Type
Sterilume™-EX
(rendimiento estándar)
Sterilume™-EX (standard-
output)
Sterilume™-EX (standard-
output)
Sterilume™-EX (standard-
output)
UV Chamber Material
304 SS
304 SS
304 SS
304 SS
1
Units ending in “/2B” have BSPT connections.
2