Maintenance

10

Section 4

Maintenance

4.1 Replacing UV Lamp

UV lamp replacement is a quick and simple procedure requiring no special tools. The UV lamp must be replaced after 9000 
hours of continuous operation (approximately one year) in order to ensure adequate disinfection.

Procedure:

WA R N I N G

  •

Always disconnect power before performing any work on the disinfection system.

  •

Always shut-off water flow and release water pressure before servicing.

  •

Regularly inspect your disinfection system to ensure that the power indicators are on and no alarms are present.

  •

Replace the UV lamp annually (or biennially if seasonal home use) to ensure maximum disinfection.

  •

Always drain the chamber when closing a seasonal home or leaving the unit in an area subject to freezing temperatures.

N O T I C E

  •

Reset UV lamp life timer after UV lamp replacement. Refer to 

Section 5.1.3

. Refer to 

www.lamprecycle.org

 for UV lamp disposal.

  •

DO NOT use water during replacement of UV lamp.

1

•   

Shut off the water line to 

chamber and release system 
pressure before servicing.

2

0

30

15

45

10 mins

•   

Disconnect main power 

source and allow the unit to 
cool for 10 minutes.

3

1

2

•   

Remove the lamp connector 

by squeezing the plastic 
locking tabs on the side of 
the connector.

4

Hg

UV

•   

Remove the lamp in upward 

direction from the chamber 
and lamp connector base.

•   

Always hold the lamp at the 

ceramic ends.

5

Hg

UV

1

2

•   

Insert the new lamp fully into 

the chamber leaving about 
two inches of the lamp 
protruding from the chamber.

6

4

2

3

1

•   

Attach the connector to the 

lamp and note that the 
connector will only allow 
correct installation in one 
position. 

7

1

2

click

•   

Push the lamp connector 

against lamp connector base 
together until an audible click 
is heard.

•   

Re-pressurize the system to 

check for leaks.

8

•   

Hold down the timer reset 

button and reapply power to 
the controller until you see 

, then release timer 

reset button.

•   

A 5 second delay will occur 

until you hear an audible tone 
and LED display will read 
once again 

.

Содержание S2Q-P/12VDC

Страница 1: ...f 1 519 763 5069 e mail info viqua com www viqua com Models S1Q PA S2Q PA S5Q PA S8Q PA S2Q P 12VDC S5Q P 12VDC NSF Standard 55 Class B Validated Models SV5Q PA SV8Q PA Owner s Manual Powered by Syste...

Страница 2: ...y should you insist on genuine factory supplied VIQUA replacement lamps Use of widely available non genuine replacement lamps has been shown to damage the control module of VIQUA UV disinfection equip...

Страница 3: ...started Warning This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm DANGER Failure to follow these instructions will resul...

Страница 4: ...d inhalation or ingestion of the debris and avoid exposure to eyes and skin Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury Obey local regulations and guid...

Страница 5: ...r long consistent life 9000 hours S287RL S1Q PA S330RL S2Q PA S463RL S5Q PA SV5Q PA S810RL S8Q PA SV8Q PA 7 Controller for 100 240V models only BA ICE S S1Q PA S2Q PA S5Q PA S8Q PA SV5Q PA SV8Q PA 8 C...

Страница 6: ...it may be exposed to the weather Install the disinfection system on cold water line only before any branched lines A 5 micron sediment filter must precede the disinfection system Ideally the disinfect...

Страница 7: ...tain the manufacturers rated flow The flow restrictor should be installed on the outlet port and is designed to be installed in one direction only Ensure that the flow of the water matches the flow di...

Страница 8: ...a leak shut water off drain cell remove the retaining nut wipe the O ring and threads Clean and re install 7 Once it is determined that there are no leaks plug the system into the ground fault interru...

Страница 9: ...ocedure for any other conditioners that may form a part of the pre treatment for the UV unit 2 The above disinfection procedure will result in a massive chlorine residual far in excess of the 0 5 to 1...

Страница 10: ...org for UV lamp disposal DO NOT use water during replacement of UV lamp 1 Shut off the water line to chamber and release system pressure before servicing 2 0 30 15 45 10 mins Disconnect main power sou...

Страница 11: ...ring 4 Carefully remove O ring adhering to the quartz sleeve Remove the quartz sleeve 5 Mild Acid Clean the quartz sleeve with a cloth soaked in CLR vinegar or some other mild acid and then rinse wit...

Страница 12: ...refer to Section 4 1 5 1 3 Resetting UV lamp Life Refer to Section 4 1 Note Even though the alarm on the system can be deferred for a period of time it is important to address each and every alarm co...

Страница 13: ...d or UV sensor Ensure O ring is in place check for cuts or abrasions clean O ring moisten with water lubricant and re install replace if necessary 410867 Condensation on UV chamber caused by excessive...

Страница 14: ...1 cm x 6 4 cm 7 3 x 3 2 x 2 5 18 6 cm x 8 1 cm x 6 4 cm 7 3 x 3 2 x 2 5 Controller 12 VDC 13 5 cm x 4 3 cm x 5 8 cm 5 3 x 1 7 x 2 3 13 5 cm x 4 3 cm x 5 8 cm 5 3 x 1 7 x 2 3 Inlet Outlet Port Size1 1...

Страница 15: ...Hardware Components VIQUA warrants the electrical controller and hardware components to be free from defects in material and workmanship for a period of three 3 years from the date of purchase During...

Страница 16: ...425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com...

Отзывы: