Specifications

15

Section 7

Specifications

IHS12-D4

IHS22-D4

IHS10-D4

Operating Parameters

Maximum operating pressure

100 PSI (689 kPa)

100 PSI (689 kPa)

100 PSI (689 kPa)

Minimum operating pressure

4 PSI (27.5 kPa)

4 PSI (27.5 kPa)

4 PSI (27.5 kPa)

Maximum ambient air temperature

122 ºF (50 ºC)

122 ºF (50 ºC)

122 ºF (50 ºC)

Minimum ambient air temperature

36 ºF (2 ºC)

36 ºF (2 ºC)

36 ºF (2 ºC)

Maximum humidity

95%

95%

95%

Maximum hardness

120 ppm (7 grains per gallon)

120 ppm (7 grains per gallon)

120 ppm (7 grains per gallon)

Maximum iron

0.3 ppm

0.3 ppm

0.3 ppm

Minimum UVT

75%

75%

75%

Flow Rates

Maximum rated flow at dose of 16 mJ/cm

2

**

16 gpm (60 lpm) (3.6 m

3

/hr)

16 gpm (60 lpm) (3.6 m

3

/hr)

16 gpm (60 lpm) (3.6 m

3

/hr)

Maximum rated flow at dose of 30 mJ/cm

2

**

12 gpm (45 lpm) (2.7 m

3

/hr)

12 gpm (45 lpm) (2.7 m

3

/hr)

12 gpm (45 lpm) (2.7 m

3

/hr)

Maximum rated flow at dose of 40 mJ/cm

2

**

9 gpm (34 lpm) (2 m

3

/hr)

9 gpm (34 lpm) (2 m

3

/hr)

9 gpm (34 lpm) (2 m

3

/hr)

Electrical

Voltage

2

100-240V AC

100-240V AC

100-240V AC

Frequency

50/60 Hz

50/60 Hz

50/60 Hz

Max. current

1 Amp

1 Amp

1 Amp

Max. power consumption

50 Watts

50 Watts

50 Watts

Lamp power

40 Watts

40 Watts

40 Watts

Other

UV Chamber Material

304 SST

304 SST

304 SST

Inlet/Outlet

3

3/4” NPT

3/4” NPT

3/4” NPT

Other

Rated service life of lamp

1 year

1 year

1 year

UV System Certification

The max flow rate is determined by the carbon filter.

**

 Flow rates shown are at 95% UVT.

2

 Units ending in "/2" are for 230V applications.

3

 Units ending in "/2B" have BSPT connections.

Содержание IHS10-D4

Страница 1: ...o Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com Models IHS10 D4 IHS12 D4 IHS22 D4 Owner s Manua...

Страница 2: ...y should you insist on genuine factory supplied VIQUA replacement lamps Use of widely available non genuine replacement lamps has been shown to damage the control module of VIQUA UV disinfection equip...

Страница 3: ...ymbol indicates there is a potential for VERY hot water when flow is started DANGER Failure to follow these instructions will result in serious injury or death Electric Shock To avoid possible electri...

Страница 4: ...f the lamp breaks then avoid inhalation or ingestion of the debris and avoid exposure to eyes and skin Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury Obey...

Страница 5: ...6 Power cord 602636 120V IHS12 D4 IHS22 D4 IHS10 D4 602637 230V IHS12 D4 2 IHS22 D4 2 IHS10 D4 2 260013 Australian IHS12 D4 2A IHS22 D4 2A IHS10 D4 2A 260012 UK IHS12 D4 2B IHS22 D4 2B IHS10 D4 2B 7 C...

Страница 6: ...hole Home System Provides filtration and disinfection of the water 6 Controller Powers and controls the UV lamp Provides human interface displaying information and allowing control inputs such as muti...

Страница 7: ...in the metal bracket 2 Slide controller onto mounting bracket 3 Insert the reference card between controller and mounting bracket 4 Connect power cord to controller DO NOT connect the power cord to t...

Страница 8: ...d any potentially harmful chemicals to the water As UV does not provide a disinfection residual it is imperative that the entire distribution system located after the UV be chemically disinfected to e...

Страница 9: ...ure Inspect for any leaks Maintenance 9 Section 4 Maintenance Always disconnect power before performing any work on the disinfection system Always shut off water flow and release water pressure before...

Страница 10: ...nd and turn lamp counter clockwise and pull the lamp outside the chamber in upward direction 5 1 2 Insert new lamp into the quartz sleeve and thread into sleeve bolt until hard stop 6 Connect the gree...

Страница 11: ...ving sleeve bolt 2 Mild Acid Clean the quartz sleeve with a cloth soaked in CLR vinegar or some other mild acid and then rinse with water Note If sleeve cannot be cleaned completely or it is scratched...

Страница 12: ...cool for 10 minutes 2 Shut off the water supply Close each faucet 3 Press the pressure button to release the pressure from the cartridges 4 Remove the drain plug at the bottom of the sump and place a...

Страница 13: ...system from main power supply 2 Check for secure lamp connection 3 Restore power to UV system 4 If failure message repeats replace UV lamp Audible alarm may be silenced for 24 Hours UV Lamp Near End...

Страница 14: ...assembly hand tight Alarm Refer to Section 5 1 Refer to Section 5 1 System is operating but water tests reveal bacterial contamination Equipment downstream of UV system is acting as a breeding ground...

Страница 15: ...hr 16 gpm 60 lpm 3 6 m3 hr 16 gpm 60 lpm 3 6 m3 hr Maximum rated flow at dose of 30 mJ cm2 12 gpm 45 lpm 2 7 m3 hr 12 gpm 45 lpm 2 7 m3 hr 12 gpm 45 lpm 2 7 m3 hr Maximum rated flow at dose of 40 mJ...

Страница 16: ...Hardware Components VIQUA warrants the electrical controller and hardware components to be free from defects in material and workmanship for a period of three 3 years from the date of purchase During...

Страница 17: ...425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com...

Отзывы: