Specifications
15
Section 7
Specifications
IHS12-D4
IHS22-D4
IHS10-D4
Operating Parameters
Maximum operating pressure
100 PSI (689 kPa)
100 PSI (689 kPa)
100 PSI (689 kPa)
Minimum operating pressure
4 PSI (27.5 kPa)
4 PSI (27.5 kPa)
4 PSI (27.5 kPa)
Maximum ambient air temperature
122 ºF (50 ºC)
122 ºF (50 ºC)
122 ºF (50 ºC)
Minimum ambient air temperature
36 ºF (2 ºC)
36 ºF (2 ºC)
36 ºF (2 ºC)
Maximum humidity
95%
95%
95%
Maximum hardness
120 ppm (7 grains per gallon)
120 ppm (7 grains per gallon)
120 ppm (7 grains per gallon)
Maximum iron
0.3 ppm
0.3 ppm
0.3 ppm
Minimum UVT
75%
75%
75%
Flow Rates
Maximum rated flow at dose of 16 mJ/cm
2
**
16 gpm (60 lpm) (3.6 m
3
/hr)
16 gpm (60 lpm) (3.6 m
3
/hr)
16 gpm (60 lpm) (3.6 m
3
/hr)
Maximum rated flow at dose of 30 mJ/cm
2
**
12 gpm (45 lpm) (2.7 m
3
/hr)
12 gpm (45 lpm) (2.7 m
3
/hr)
12 gpm (45 lpm) (2.7 m
3
/hr)
Maximum rated flow at dose of 40 mJ/cm
2
**
9 gpm (34 lpm) (2 m
3
/hr)
9 gpm (34 lpm) (2 m
3
/hr)
9 gpm (34 lpm) (2 m
3
/hr)
Electrical
Voltage
2
100-240V AC
100-240V AC
100-240V AC
Frequency
50/60 Hz
50/60 Hz
50/60 Hz
Max. current
1 Amp
1 Amp
1 Amp
Max. power consumption
50 Watts
50 Watts
50 Watts
Lamp power
40 Watts
40 Watts
40 Watts
Other
UV Chamber Material
304 SST
304 SST
304 SST
Inlet/Outlet
3
3/4” NPT
3/4” NPT
3/4” NPT
Other
Rated service life of lamp
1 year
1 year
1 year
UV System Certification
1
The max flow rate is determined by the carbon filter.
**
Flow rates shown are at 95% UVT.
2
Units ending in "/2" are for 230V applications.
3
Units ending in "/2B" have BSPT connections.