9
•
Connect the green ground
wire and red strain relief wire
to the chamber using the
grounding screw.
10
10
•
Align connection pins with
the lamp connector by
rotating the ring clamp.
•
Push the lamp connector
down onto the lamp pins and
the ring clamp pins until an
audible click is heard.
Note:
Ensure the connector
is engaged on both sides.
11
11
•
Connect power.
•
Open all faucets and turn on
water supply. Inspect for any
leaks.
Note:
Outlet must be
protected by a Ground Fault
Circuit Interrupter (GFCI).
Installation
8
3.2 Disinfection Procedure
Prerequisites:
•
Reapply a generous amount of lubricant to the O-ring when reinstalling sumps.
Procedure:
UV disinfection is a physical disinfection process and does not add any potentially harmful chemicals to the water. As UV
does not provide a disinfection residual, it is imperative that the entire distribution system located after the UV be chemically
disinfected to ensure that the plumbing system is free from any bacteriological contaminants. The disinfection process must
be performed immediately after the UV unit is installed and repeated thereafter whenever the UV is shut down for service,
without power, or inoperative for any reason. The procedure for sanitizing the plumbing system is readily accomplished as
follows:
1
•
Ensure the controller is
plugged in for entire
disinfection process.
2
•
Shut off the water supply.
•
Close each faucet.
3
•
Press the pressure button to
release the pressure from the
cartridges
4
•
Remove the drain plug at the
bottom of the sump and place
a pail to catch the water.
•
Reinstall the drain plug.
C A U T I O N
The sump housings will be heavy.